Literature DB >> 22865867

Cost-effectiveness of presentation versus delayed troponin testing for acute myocardial infarction.

Praveen Thokala1, Steve W Goodacre, Paul O Collinson, John W Stevens, Nicholas L Mills, David E Newby, Francis Morris, Jason Kendall, Matt D Stevenson.   

Abstract

OBJECTIVES: To estimate the cost-effectiveness of delayed troponin testing for myocardial infarction compared with troponin testing at presentation.
DESIGN: Decision analysis modelling of cost-effectiveness using secondary data sources.
SETTING: Acute hospitals in the UK. POPULATION: Patients attending hospital with suspected myocardial infarction but a normal or non-diagnostic ECG and no major comorbidities requiring admission.
INTERVENTIONS: Delayed troponin testing (10 h after symptom onset) compared with standard and high-sensitivity troponin testing at presentation and no testing. Sensitivity analysis evaluated high-sensitivity troponin testing 3 h after initial assessment. MAIN OUTCOME MEASURES: The incremental cost per quality-adjusted life year (QALY) gained by each strategy, compared with the next most effective alternative, and the probability of each strategy being cost-effective at varying willingness-to-pay per QALY gained.
RESULTS: In all scenarios tested, presentation high-sensitivity troponin testing was the most effective strategy with an incremental cost-effectiveness ratio below the £20 000/QALY threshold. 10 h troponin testing was only likely to be cost-effective if a discharge decision could be made as soon as a negative result was available and the £30 000/QALY threshold was used, or if a lower sensitivity estimate for presentation high-sensitivity troponin was assumed. Sensitivity analysis showed that including high-sensitivity troponin testing at presentation and 3 h in the analysis makes this the most cost-effective strategy.
CONCLUSIONS: Delayed troponin testing is unlikely to be cost-effective compared with high-sensitivity troponin testing at presentation in most scenarios. Current NICE chest pain guidelines do not promote cost-effective care.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22865867     DOI: 10.1136/heartjnl-2012-302188

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  11 in total

Review 1.  Economic Evidence and Point-of-Care Testing.

Authors:  Andrew St John; Christopher P Price
Journal:  Clin Biochem Rev       Date:  2013-08

2.  Resource modelling: the missing piece of the HTA jigsaw?

Authors:  Praveen Thokala; Simon Dixon; Beate Jahn
Journal:  Pharmacoeconomics       Date:  2015-03       Impact factor: 4.981

3.  A novel diagnostic protocol to identify patients suitable for discharge after a single high-sensitivity troponin.

Authors:  Edward W Carlton; Louise Cullen; Martin Than; James Gamble; Ahmed Khattab; Kim Greaves
Journal:  Heart       Date:  2015-02-17       Impact factor: 5.994

4.  High-sensitive troponin T assay for the diagnosis of acute myocardial infarction: an economic evaluation.

Authors:  Anil Vaidya; Johan L Severens; Brenda W C Bongaerts; Kitty B J M Cleutjens; Patty J Nelemans; Leonard Hofstra; Marja van Dieijen-Visser; Erik A L Biessen
Journal:  BMC Cardiovasc Disord       Date:  2014-06-13       Impact factor: 2.298

5.  The RAPID-CTCA trial (Rapid Assessment of Potential Ischaemic Heart Disease with CTCA) - a multicentre parallel-group randomised trial to compare early computerised tomography coronary angiography versus standard care in patients presenting with suspected or confirmed acute coronary syndrome: study protocol for a randomised controlled trial.

Authors:  Alasdair J Gray; Carl Roobottom; Jason E Smith; Steve Goodacre; Katherine Oatey; Rachel O'Brien; Robert F Storey; Lumine Na; Steff C Lewis; Praveen Thokala; David E Newby
Journal:  Trials       Date:  2016-12-07       Impact factor: 2.279

6.  Diagnostic performance of point-of-care and central laboratory cardiac troponin assays in an emergency department.

Authors:  Petra Wilke; Annette Masuch; Oliver Fahron; Stephanie Zylla; Tobias Leipold; Astrid Petersmann
Journal:  PLoS One       Date:  2017-11-28       Impact factor: 3.240

7.  The organisational value of diagnostic strategies using high-sensitivity troponin for patients with possible acute coronary syndromes: a trial-based cost-effectiveness analysis.

Authors:  Paul Jülicher; Jaimi H Greenslade; William A Parsonage; Louise Cullen
Journal:  BMJ Open       Date:  2017-06-09       Impact factor: 2.692

8.  Evidence and Cost Effectiveness Requirements for Recommending New Biomarkers.

Authors:  Paul Collinson
Journal:  EJIFCC       Date:  2015-08-24

9.  Randomised controlled trial of the Limit of Detection of Troponin and ECG Discharge (LoDED) strategy versus usual care in adult patients with chest pain attending the emergency department: study protocol.

Authors:  Edward Carlton; Sarah Campbell; Jenny Ingram; Rebecca Kandiyali; Hazel Taylor; Shahid Aziz; Peter Beresford; Jason Kendall; Adam Reuben; Jason Smith; Patricia Jane Vickery; Jonathan Richard Benger
Journal:  BMJ Open       Date:  2018-10-02       Impact factor: 2.692

10.  Limit of detection of troponin discharge strategy versus usual care: randomised controlled trial.

Authors:  Edward Watts Carlton; Jenny Ingram; Hazel Taylor; Joel Glynn; Rebecca Kandiyali; Sarah Campbell; Lucy Beasant; Shahid Aziz; Peter Beresford; Jason Kendall; Adam Reuben; Jason E Smith; Rebecca Chapman; Siobhan Creanor; Jonathan Richard Benger
Journal:  Heart       Date:  2020-05-05       Impact factor: 5.994

View more