OBJECTIVES: To evaluate the occurrence of coring after needle insertion through the rubber stopper of prednisolone acetate vials.
METHODS: Two-hundred vials of prednisolone acetate were randomly distributed to two radiologists. Prednisolone acetate was drawn up through the rubber bung of the vials with an 18-gauge cutting bevelled needle and aspirated with a 5-ml syringe. The presence of coring was noted visually. We systematically put each core in a syringe refilled with 3 ml prednisolone acetate, and injected the medication through a 20-gauge spine needle. Computed tomography was performed to measure the size of each coring.
RESULTS: Coring occurred in 21 out of 200 samples (10.5 %), and was visually detected in the syringe filled up with prednisolone in 11 of the 21 cases. Ten more occult cores were detected only after the syringes and needles were taken apart and rinsed. The core size ranged from 0.6 to 1.1 mm, and 1 of the 21 (4.7 %) cores was ejected through the 20-gauge needle.
CONCLUSION: Coring can occur after the insertion of a needle through the rubber stopper of a vial of prednisolone acetate, and the resultant core can then be aspirated into the syringe.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22865273     DOI: 10.1007/s00330-012-2602-3

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  [A case of coring on using a 1% Diprivan vial].

Authors:  Y Adachi; J Takigami; K Watanabe; T Satoh
Journal:  Masui       Date:  2001-06

2.  Occurrence of coring in insulin vials and possibility of rubber piece contamination by self-injection.

Authors:  T Asakura; H Seino; S Nozaki; R Abe
Journal:  Yakugaku Zasshi       Date:  2001-06       Impact factor: 0.302

3.  Preventing rubber stopper coring.

Authors:  G Nicol
Journal:  Anaesthesia       Date:  2002-02       Impact factor: 6.955

4.  Particulate matter contamination of intravenous antibiotics aggravates loss of functional capillary density in postischemic striated muscle.

Authors:  Hans-Anton Lehr; Joachim Brunner; Ramzan Rangoonwala; C James Kirkpatrick
Journal:  Am J Respir Crit Care Med       Date:  2002-02-15       Impact factor: 21.405

5.  The incidence of "coring" during aspiration of propofol from a 50-ml vial.

Authors:  K Shiroyama
Journal:  J Anesth       Date:  2001       Impact factor: 2.078

6.  Potential foreign body emboli associated with botulinum toxin A injections.

Authors:  Kenneth Beer
Journal:  J Drugs Dermatol       Date:  2007-02       Impact factor: 2.114

Review 7.  Injectable corticosteroid and local anesthetic preparations: a review for radiologists.

Authors:  Peter J MacMahon; Stephen J Eustace; Eoin C Kavanagh
Journal:  Radiology       Date:  2009-09       Impact factor: 11.105

8.  Coring: a potential problem in eye surgery.

Authors:  H A Stein; B L Vu
Journal:  J Cataract Refract Surg       Date:  1994-03       Impact factor: 3.351

Review 9.  Adverse central nervous system sequelae after selective transforaminal block: the role of corticosteroids.

Authors:  Robert L Tiso; Thomas Cutler; Joseph A Catania; Karen Whalen
Journal:  Spine J       Date:  2004 Jul-Aug       Impact factor: 4.166

Review 10.  Paraplegia complicating selective steroid injections of the lumbar spine. Report of five cases and review of the literature.

Authors:  Marc Wybier; Sandrine Gaudart; David Petrover; Emmanuel Houdart; Jean-Denis Laredo
Journal:  Eur Radiol       Date:  2009-08-14       Impact factor: 5.315

View more
  1 in total

1.  The impact of needle size and angle on rubber coring after multiple puncturing of multi-dose propofol vial rubber stoppers.

Authors:  Thanyarat Chotikawanich; Thipaporn Kammee; Sirikarn Khantee
Journal:  Heliyon       Date:  2022-05-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.