Literature DB >> 22864552

Retrospective analysis of outcome data with regards to the use of Phisio®-, Bioline®- or Softline®-coated cardiopulmonary bypass circuits in cardiac surgery.

D Reser1, B Seifert, M Klein, T Dreizler, P Hasenclever, V Falk, C Starck.   

Abstract

BACKGROUND: Numerous cardiopulmonary bypass circuits with various coatings designed to reduce the inflammatory response and to provide better hemocompatibility are available. The aim of this study was to compare the effect of phosphorylcholine-coated, albumin-heparin-coated and synthetic polymer-coated perfusion tubing systems on patient outcome.
METHODS: We performed a retrospective database review of elective patients between January 1st 2010 and December 31st 2010. Demographics, preoperative, operative, postoperative data and follow-up were collected and statistically analysed.
RESULTS: We identified 201 patients and formed three groups: Group 1 with phosphorylcholine coating (n=133), Group 2 with albumin-heparin coating (n=32) and Group 3 synthetic polymer coating (n=36). Mean age was 68 ± 11 years, additive Euroscore 5.8 ± 2.7. In-hospital outcomes were comparable between the groups without statistically significant differences. The overall 30-day and 1-year late survival were 98.5% and 96.7 ± 1.9%, respectively.
CONCLUSIONS: Our findings suggest that in-hospital and follow-up outcomes are comparable in cardiac surgery patients after using either phosphorylcholine-coated, albumin-heparin-coated or synthetic polymer-coated circuits during cardiopulmonary bypass.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22864552     DOI: 10.1177/0267659112454558

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  9 in total

1.  Nitric oxide-generating compound and bio-clickable peptide mimic for synergistically tailoring surface anti-thrombogenic and anti-microbial dual-functions.

Authors:  Han Yu; Shaoxing Yu; Hua Qiu; Peng Gao; Yingzhong Chen; Xin Zhao; Qiufen Tu; Minggang Zhou; Lin Cai; Nan Huang; Kaiqin Xiong; Zhilu Yang
Journal:  Bioact Mater       Date:  2020-11-23

Review 2.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

3.  Heparin-coated cardiopulmonary bypass circuits selectively deplete the pattern recognition molecule ficolin-2 of the lectin complement pathway in vivo.

Authors:  E Hein; L Munthe-Fog; A S Thiara; A E Fiane; T E Mollnes; P Garred
Journal:  Clin Exp Immunol       Date:  2015-02       Impact factor: 4.330

4.  Hemodynamic Performance and Thrombogenic Properties of a Superhydrophobic Bileaflet Mechanical Heart Valve.

Authors:  David L Bark; Hamed Vahabi; Hieu Bui; Sanli Movafaghi; Brandon Moore; Arun K Kota; Ketul Popat; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-04-20       Impact factor: 3.934

5.  The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

Authors:  David L Bark; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2015-09-28       Impact factor: 3.934

6.  A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling.

Authors:  Daniel C Leslie; Anna Waterhouse; Julia B Berthet; Thomas M Valentin; Alexander L Watters; Abhishek Jain; Philseok Kim; Benjamin D Hatton; Arthur Nedder; Kathryn Donovan; Elana H Super; Caitlin Howell; Christopher P Johnson; Thy L Vu; Dana E Bolgen; Sami Rifai; Anne R Hansen; Michael Aizenberg; Michael Super; Joanna Aizenberg; Donald E Ingber
Journal:  Nat Biotechnol       Date:  2014-10-12       Impact factor: 54.908

7.  Toward an artificial endothelium: Development of blood-compatible surfaces for extracorporeal life support.

Authors:  Teryn R Roberts; Mark R S Garren; Hitesh Handa; Andriy I Batchinsky
Journal:  J Trauma Acute Care Surg       Date:  2020-08       Impact factor: 3.697

Review 8.  Modification strategies to improve the membrane hemocompatibility in extracorporeal membrane oxygenator (ECMO).

Authors:  Ting He; Jinhui He; Zhaohui Wang; Zhaoliang Cui
Journal:  Adv Compos Hybrid Mater       Date:  2021-05-03

9.  Impact of cannula design on packed red blood cell transfusions: technical advancement to improve outcomes in extracorporeal membrane oxygenation.

Authors:  Gennaro Martucci; Giovanna Panarello; Giovanna Occhipinti; Giuseppe Raffa; Fabio Tuzzolino; Guido Capitanio; Tiziana Carollo; Giovanni Lino; Alessandro Bertani; Patrizio Vitulo; Michele Pilato; Roberto Lorusso; Antonio Arcadipane
Journal:  J Thorac Dis       Date:  2018-10       Impact factor: 2.895

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.