Literature DB >> 22862418

Parental interaction with infants treated with medical technology.

Björn Lantz1, Cornelia Ottosson.   

Abstract

BACKGROUND: It is well established that parents must interact with their new-born babies to facilitate attachment. However, very little is known about how parents perceive different types of medical technology products commonly used in the neonatal intensive care unit (NICU) as barriers to their wish to interact with their infants. AIM: This study aims to examine to what extent the different medical technology products commonly used in the NICU are perceived by parents to be obstacles in their wish to interact with their babies. DESIGN AND METHODS: In 2010, a cross-sectional survey, using a questionnaire specifically developed for this study, was conducted among the parents of children who were discharged from any of the five NICUs of the Västra Götaland region in Sweden. A consecutive sample of 248 parents participated, and multiple regressions and t-tests were used to analyse the data.
RESULTS: The parents generally perceived the various medical technology products differently, according to the perceived level of obstruction. The variables of gender, age, educational level, origin, gestational age, previous experience of being a parent, and the offer of accommodation at the NICU were significantly associated with the perceived level of obstruction in the parents' wish to interact with their baby while the baby was being treated with different medical technology products.
CONCLUSION: The primary implication for practice is that to facilitate attachment, nurses should involve different categories of parents in different ways in the care of their children, depending on the equipment being used in the treatment of the children. Thus, the individual care plan should explicitly include the details of the specific medical equipment, because although its use is medically beneficial for the child, it is associated with potential liabilities regarding parent-child interaction and, consequently, regarding parent-child attachment.
© 2012 The Authors. Scandinavian Journal of Caring Sciences © 2012 Nordic College of Caring Science.

Entities:  

Keywords:  incubator; infusion; monitoring; neonatal intensive care unit; nursing; parental interaction with infants; phototherapy; respiratory support

Mesh:

Year:  2012        PMID: 22862418     DOI: 10.1111/j.1471-6712.2012.01061.x

Source DB:  PubMed          Journal:  Scand J Caring Sci        ISSN: 0283-9318


  2 in total

1.  'There were more wires than him': the potential for wireless patient monitoring in neonatal intensive care.

Authors:  Oliver Bonner; Kathryn Beardsall; Nathan Crilly; Joan Lasenby
Journal:  BMJ Innov       Date:  2017-01-04

2.  Health-related quality of life and its determinants in children with a congenital diaphragmatic hernia.

Authors:  Fabrice Michel; Karine Baumstarck; Agathe Gosselin; Pierre Le Coz; Thierry Merrot; Sophie Hassid; Kathia Chaumoître; Julie Berbis; Claude Martin; Pascal Auquier
Journal:  Orphanet J Rare Dis       Date:  2013-06-20       Impact factor: 4.123

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.