Literature DB >> 22855318

Treatment of complex intracranial aneurysms with a telescoping stent technique.

Nohra Chalouhi1, Peter Campbell, Yamane Makke, Sanjay Yadla, Aaron S Dumont, L Fernando Gonzalez, Stavropoula Tjoumakaris, Barbara Albani, Robert H Rosenwasser, Pascal Jabbour.   

Abstract

BACKGROUND AND OBJECT: Complex intracranial aneurysms present a treatment challenge for both open and endovascular modalities of treatment. This report seeks to illustrate a series of patients with aneurysms treated with telescoping stents as a method of flow diversion for small and fusiform intracranial aneurysms.
MATERIAL AND METHODS: A retrospective evaluation of six patients treated with a telescoping stent technique utilizing available stents (at that time before the pipeline era) for complex cerebral aneurysms between January 2009 and January 2010 was performed. Five patients had dissecting aneurysms and one patient had a small superior hypophyseal artery aneurysm. One of the patients was treated in the setting of a Hunt and Hess grade IV subarachnoid hemorrhage. Follow-up cerebral angiography was performed postprocedure at 6 months.
RESULTS: At a mean follow-up period of 9 months, all the patients experienced complete or near-complete occlusion (>95%). No periprocedural complications were noted in this series. No episodes of hemorrhage or thromboembolic complications occurred.
CONCLUSIONS: Overlapping Neuroform and Enterprise stents may induce complete thrombosis of intracranial aneurysms and facilitate parent artery remodeling. The use of self-expanding stents is still an adequate treatment modality, especially if there is a need for vessel wall stabilization rather than flow diversion. The technique is also a sufficient alternative in small intracranial aneurysms not readily amenable to open surgical treatment or traditional endovascular coil embolization. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Year:  2012        PMID: 22855318     DOI: 10.1055/s-0032-1322589

Source DB:  PubMed          Journal:  J Neurol Surg A Cent Eur Neurosurg        ISSN: 2193-6315            Impact factor:   1.268


  2 in total

1.  Risk factors for repeated recurrence of cerebral aneurysms treated with endovascular embolization.

Authors:  Yong-Feng Han; Peng Jiang; Zhong-Bin Tian; Xi-Heng Chen; Jian Liu; Zhong-Xue Wu; Bu-Lang Gao; Chun-Feng Ren
Journal:  Front Neurol       Date:  2022-09-29       Impact factor: 4.086

2.  Tied Pipeline: A Case of Rare Complication.

Authors:  Shigeru Miyachi; Hiroyuki Ohnishi; Ryo Hiramatsu; Ryokichi Yagi; Toshihiko Kuroiwa
Journal:  Neurol Med Chir (Tokyo)       Date:  2018-05-01       Impact factor: 1.742

  2 in total