Public safety assessment of electromagnetic radiation exposure from mobile base stations.

Z O Alhekail1, M A Hadi, M A Alkanhal.   

Abstract

Exposure of the general public to electromagnetic radiation originating from randomly selected GSM/WCDMA base stations in Riyadh, Kingdom of Saudi Arabia has been assessed in the context of the International Commission on Non-Ionising Radiation Protection (ICNIRP) guidelines. The purpose of the measurement was to record the maximum power density of signals to estimate possible worst case exposure at each measurement location. These power density measurements were carried out at 60 mobile base stations located in different regions of the city. For each of these sites, three sectors were operational, yielding a total of 180 sectors. Two positions were identified per site with the greatest power density values. Exposures from these base stations were generally found to be in the range of 0.313 to 0.00000149% of the ICNIRP general public reference level, and the greatest exposure near any of the base stations was 21.96 mW m(-2) for a wideband measurement in the 75-3000 MHz frequency range. Analysis of the measured data reveals several trends for different mobile bands with respect to maximum exposure in those locations. Additionally, a simplified calculation method for the electromagnetic fields was used to compare calculated and the measured data. It was determined, on the basis of both results of the measurements and calculations carried out for these selected base stations, that members of the public would not be exposed to in excess of a small fraction of the ICNIRP guidelines at any of those sites. These are first such measurements to be made in the Middle East and provide assurance that exposures in this region of the world do not seem to be any greater than elsewhere.

Mesh:

Year:  2012        PMID: 22854221     DOI: 10.1088/0952-4746/32/3/325

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  2 in total

1.  A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations.

Authors:  Raimondas Buckus; Birute Strukčinskienė; Juozas Raistenskis; Rimantas Stukas; Aurelija Šidlauskienė; Rimantė Čerkauskienė; Dorina Nicolina Isopescu; Jan Stabryla; Igor Cretescu
Journal:  Int J Environ Res Public Health       Date:  2017-03-01       Impact factor: 3.390

2.  National surveys of radiofrequency field strengths from radio base stations in Africa.

Authors:  Ken H Joyner; Marthinus J Van Wyk; Jack T Rowley
Journal:  Radiat Prot Dosimetry       Date:  2013-09-17       Impact factor: 0.972

  2 in total