Literature DB >> 22851221

Regional variations of T₂* in healthy and pathologic achilles tendon in vivo at 7 Tesla: preliminary results.

Vladimir Juras1, Stefan Zbyn, Christina Pressl, Ladislav Valkovic, Pavol Szomolanyi, Ivan Frollo, Siegfried Trattnig.   

Abstract

The aim of this study was to investigate T₂* in the Achilles tendon (AT), in vivo, using a three-dimensional ultrashort time echo (3D-UTE) sequence, to compare field strength differences (3 and 7 T) and to evaluate a regional variation of T₂* in healthy and pathologic tendon. Ten volunteers with no history of pain in the AT and five patients with chronic Achilles tendinopathy were recruited. 3D-UTE images were measured with the following echo times, at echo time = [0.07, 0.2, 0.33, 0.46, 0.59, 0.74, 1.0, 1.5, 2.0, 4.0, 6.0, and 9.0 ms]. T₂* values in the AT were calculated by fitting the signal decay to biexponential function. Comparing volunteers between 3 and 7 T, short component T(2s)* was 0.71 ± 0.17 ms and 0.34 ± 0.09 ms (P < 0.05); bulk long component T(2l)* was 12.85 ± 1.87 ms and 10.28 ± 2.28 ms (P < 0.05). In patients at 7 T, bulk T(2s)* was 0.53 ± 0.17 ms (P = 0.045, compared to volunteers), T(2l)* was 11.49 ± 4.28 ms (P = 0.99, compared to volunteers). The results of this study suggest that the regional variability of AT can be quantified by T₂* in in vivo conditions. Advanced quantitative imaging of the human AT using a 3D-UTE sequence may provide additional information to standard clinical imaging. Finally, as the preliminary patient data suggest, T(2s)* may be a promising marker for the diagnosis of pathological changes in the AT.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22851221     DOI: 10.1002/mrm.24136

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Bicomponent ultrashort echo time T2* analysis for assessment of patients with patellar tendinopathy.

Authors:  Richard Kijowski; John J Wilson; Fang Liu
Journal:  J Magn Reson Imaging       Date:  2017-03-06       Impact factor: 4.813

2.  Quantitative bi-component T2* analysis of histologically normal Achilles tendons.

Authors:  Eric Y Chang; Jiang Du; Sheronda Statum; Chantal Pauli; Christine B Chung
Journal:  Muscles Ligaments Tendons J       Date:  2015-07-03

3.  Peripheral nerve MRI: precision and reproducibility of T2*-derived measurements at 3.0-T : a feasibility study.

Authors:  Alberto Tagliafico; Bianca Bignotti; Giulio Tagliafico; Carlo Martinoli
Journal:  Skeletal Radiol       Date:  2015-01-30       Impact factor: 2.199

4.  Assessment of different fitting methods for in-vivo bi-component T2* analysis of human patellar tendon in magnetic resonance imaging.

Authors:  Fang Liu; Richard Kijowski
Journal:  Muscles Ligaments Tendons J       Date:  2017-05-10

Review 5.  Quantitative techniques for musculoskeletal MRI at 7 Tesla.

Authors:  Neal K Bangerter; Meredith D Taylor; Grayson J Tarbox; Antony J Palmer; Daniel J Park
Journal:  Quant Imaging Med Surg       Date:  2016-12

6.  Quantitative assessment of the supraspinatus tendon on MRI using T2/T2* mapping and shear-wave ultrasound elastography: a pilot study.

Authors:  Konstantin Krepkin; Mary Bruno; José G Raya; Ronald S Adler; Soterios Gyftopoulos
Journal:  Skeletal Radiol       Date:  2016-11-28       Impact factor: 2.199

7.  Depiction of achilles tendon microstructure in vivo using high-resolution 3-dimensional ultrashort echo-time magnetic resonance imaging at 7 T.

Authors:  Misung Han; Peder E Z Larson; Jing Liu; Roland Krug
Journal:  Invest Radiol       Date:  2014-05       Impact factor: 6.016

8.  Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

Authors:  Behnam Namiranian; Saeed Jerban; Yajun Ma; Erik W Dorthe; Amir Masoud-Afsahi; Jonathan Wong; Zhao Wei; Yanjun Chen; Darryl D'Lima; Eric Y Chang; Jiang Du
Journal:  J Biomech       Date:  2020-10-24       Impact factor: 2.712

9.  Ultrashort echo time T2 values decrease in tendons with application of static tensile loads.

Authors:  Saeed Jerban; Amin Nazaran; Xin Cheng; Michael Carl; Nikolaus Szeverenyi; Jiang Du; Eric Y Chang
Journal:  J Biomech       Date:  2017-07-25       Impact factor: 2.712

10.  Quantitative magnetization transfer ultrashort echo time imaging using a time-efficient 3D multispoke Cones sequence.

Authors:  Ya-Jun Ma; Eric Y Chang; Michael Carl; Jiang Du
Journal:  Magn Reson Med       Date:  2017-05-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.