Literature DB >> 22848888

Cement application techniques in luting implant-supported crowns: a quantitative and qualitative survey.

Chandur Wadhwani1, Timothy Hess, Alfonso Piñeyro, Richard Opler, Kwok-Hung Chung.   

Abstract

PURPOSE: To investigate different techniques used by dentists when luting an implant-supported crown and to evaluate the application of cement quantitatively and qualitatively.
MATERIALS AND METHODS: Participants were given a bag containing cement sachet, mixing pad, spatula, a variety of application instruments, and a polycarbonate crown form. The participants were instructed with a standardized audio-video presentation to proportion the cement, mix it, and apply it to the intaglio of the crown as they would if they were to cement it onto an implant abutment in a clinical situation. The crowns were weighed, first unfilled and then again once the applied cement had set. The mean weights of fully-loaded crowns (n = 10) were used as a control group. The patterns of cement loading were recorded. The weights of collected cement-loaded crowns were compared to those of the control group and analyzed statistically.
RESULTS: Four hundred and one dentists in several different geographic locations were surveyed. Three distinct cement loading patterns were observed: gross application (GA), brush-on application (BA), and margin application (MA). The mean weights for each cement loading pattern were 242.2 mg for the GA group, 59.9 mg for the BA group, and 59.0 mg for the MA group. The weight of cement in the GA group was significantly higher than that in the other groups. No statistically significant difference between groups BA and MA was seen.
CONCLUSIONS: The diversity of the cement loading patterns disclosed in this study indicates that there is a lack of uniformity and precision in methods and a lack of consensus in the dental community regarding the appropriate quantity of cement and placement method for a cement-retained implant crown.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22848888

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  3 in total

1.  In Vitro Evaluation of Planktonic Growth on Experimental Cement-Retained Titanium Surfaces.

Authors:  Nur Balci; Umut Cakan; Burak Aksu; Oncu Akgul; Nurver Ulger
Journal:  Med Sci Monit       Date:  2016-04-08

2.  Influence of margin location and luting material on the amount of undetected cement excess on CAD/CAM implant abutments and cement-retained zirconia crowns: an in-vitro study.

Authors:  Peter Gehrke; Konstantin Bleuel; Carsten Fischer; Robert Sader
Journal:  BMC Oral Health       Date:  2019-06-14       Impact factor: 2.757

3.  A finite element analysis of novel vented dental abutment geometries for cement-retained crown restorations.

Authors:  Lucas C Rodriguez; Juliana N Saba; Clark A Meyer; Kwok-Hung Chung; Chandur Wadhwani; Danieli C Rodrigues
Journal:  Clin Exp Dent Res       Date:  2016-06-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.