Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

Xu Duan1, Feng Ling, Yun Shen, Jun Yang, Hai-ying Xu, Xiao-shan Tong.   

Abstract

AIMS: We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. METHODS AND
RESULTS: A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group.
CONCLUSION: Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22848074     DOI: 10.1093/europace/eus233

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  Coronary sinus catheter placement via left cubital vein for phrenic nerve stimulation during pulmonary vein isolation.

Authors:  Akio Chikata; Takeshi Kato; Kazuo Usuda; Shuhei Fujita; Michiro Maruyama; Kan-Ichi Otowa; Shin-Ichiro Takashima; Hisayoshi Murai; Soichiro Usui; Hiroshi Furusho; Shuichi Kaneko; Masayuki Takamura
Journal:  Heart Vessels       Date:  2019-04-10       Impact factor: 2.037

2.  Cephalic vein cut-down technique for severe venous spasm following axillary vein puncture at pacemaker implantation.

Authors:  Takashi Hiruma; Takahiko Nagase; Kanki Inoue; Junichi Nitta; Mitsuaki Isobe
Journal:  J Cardiol Cases       Date:  2022-06-01

3.  An unyielding valve leading to venous spasm during pacemaker implantation: a case report.

Authors:  Darshan Krishnappa; Scott Sakaguchi; Ganesh Kasinadhuni; Venkatakrishna N Tholakanahalli
Journal:  Eur Heart J Case Rep       Date:  2019-09-27

4.  A Case Report of Brachiocephalic Vein Spasm Secondary to Peripherally Inserted Central Catheter.

Authors:  Seth Russell; Jordan H Chamberlin; Jeremy R Burt; Ismail M Kabakus
Journal:  Cureus       Date:  2022-07-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.