Literature DB >> 22847153

Application of a new microcantilever biosensor resonating at the air-liquid interface for direct insulin detection and continuous monitoring of enzymatic reactions.

Jungwook Park1, Stanislav L Karsten, Shuhei Nishida, Hideki Kawakatsu, Hiroyuki Fujita.   

Abstract

Here we describe the application of a recently developed high-resolution microcantilever biosensor resonating at the air-liquid interface for the continuous detection of antigen-antibody and enzyme-substrate interactions. The cantilever at the air-liquid interface demonstrated 50% higher quality factor and a 5.7-fold increase in signal-to-noise-ratio (SNR) compared with one immersed in the purified water. First, a label-free detection of a low molecular weight protein (insulin, 5.8 kDa) in physiological concentration was demonstrated. The liquid facing side of the cantilever was functionalized by coating its surface with insulin antibodies, while the opposite side was exposed to air. The meniscus membrane at the micro-slit around the cantilever sustained the liquid in the microchannel. After optimizing the process of surface functionalization, the resonance frequency shift was successfully measured for insulin solutions of 0.4, 2.0, and 6.3 ng ml(-1). To demonstrate additional application of the device for monitoring enzymatic protein degradation, the liquid facing microcantilever surface was coated with human recombinant SOD1 (superoxide dismutase 1) and exposed to various concentrations of proteinase K solution, and the kinetics of the SOD1 digestion was continuously monitored. The results showed that it is a suitable tool for sensitive protein detection and analysis.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22847153     DOI: 10.1039/c2lc40232g

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  3 in total

Review 1.  Cellular and biomolecular detection based on suspended microchannel resonators.

Authors:  Juhee Ko; Jaewoo Jeong; Sukbom Son; Jungchul Lee
Journal:  Biomed Eng Lett       Date:  2021-09-12

2.  A suspended graphene-based optical interferometric surface stress sensor for selective biomolecular detection.

Authors:  Shin Kidane; Hayato Ishida; Kazuaki Sawada; Kazuhiro Takahashi
Journal:  Nanoscale Adv       Date:  2020-03-19

Review 3.  Fabricating Silicon Resonators for Analysing Biological Samples.

Authors:  Momoko Kumemura; Deniz Pekin; Vivek Anand Menon; Isabelle Van Seuningen; Dominique Collard; Mehmet Cagatay Tarhan
Journal:  Micromachines (Basel)       Date:  2021-12-12       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.