Literature DB >> 22846890

EDS measurements of X-ray intensity at WDS precision and accuracy using a silicon drift detector.

Nicholas W M Ritchie1, Dale E Newbury, Jeffrey M Davis.   

Abstract

The accuracy and precision of X-ray intensity measurements with a silicon drift detector (SDD) are compared with the same measurements performed on a wavelength dispersive spectrometer (WDS) for a variety of elements in a variety of materials. In cases of major (>0.10 mass fraction) and minor (>0.01 mass fraction) elements, the SDD is demonstrated to perform as well or better than the WDS. This is demonstrated both for simple cases in which the spectral peaks do not interfere (SRM-481, SRM-482, and SRM-479a), and for more difficult cases in which the spectral peaks have significant interferences (the Ba L/Ti K lines in a series of Ba/Ti glasses and minerals). We demonstrate that even in the case of significant interference high count SDD spectra are capable of accurately measuring Ti in glasses with Ba:Ti mass fraction ratios from 2.7:1 to 23.8:1. The results suggest that for many measurements wavelength spectrometry can be replaced with an SDD with improved accuracy and precision.

Entities:  

Year:  2012        PMID: 22846890     DOI: 10.1017/S1431927612001109

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  4 in total

1.  Enhanced Versatility of Table-Top X-Rays from Van der Waals Structures.

Authors:  Sunchao Huang; Ruihuan Duan; Nikhil Pramanik; Chris Boothroyd; Zheng Liu; Liang Jie Wong
Journal:  Adv Sci (Weinh)       Date:  2022-03-31       Impact factor: 17.521

2.  Comparison of surface aspects of turned and anodized titanium dental implant, or abutment material for an optimal soft tissue integration.

Authors:  Attila Mühl; Péter Szabó; Olga Krafcsik; Zoltán Aigner; Judit Kopniczky; Gyula Marada; Kinga Turzó
Journal:  Heliyon       Date:  2022-08-15

3.  Energy drinks alter the surface morphology and roughness of composites, fissure sealants and titanium: An in vitro study.

Authors:  Béla Kolarovszki; Alíz Sándor; Péter Szabó; Judit Kopniczky; Dorottya Frank; Ákos Nagy; Kinga Turzó
Journal:  Heliyon       Date:  2022-09-26

Review 4.  Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS).

Authors:  Dale E Newbury; Nicholas W M Ritchie
Journal:  J Mater Sci       Date:  2014-11-12       Impact factor: 4.220

  4 in total