Literature DB >> 22845715

Pulse transit time as a quick predictor of a successful axillary brachial plexus block.

M C Kortekaas1, S P Niehof, M H N van Velzen, E M Galvin, F J P M Huygen, R J Stolker.   

Abstract

BACKGROUND: It can take up to 30 min to determine whether or not axillary block has been successful. Pulse transit time (PTT) is the time between the R-wave on electrocardiography (ECG) and the arrival of the resulting pressure pulse wave in the fingertip measured with photoplethysmography. It provides information about arterial resistance. Axillary block affects vasomotor tone causing loss of sympathetic vasoconstriction resulting in an increased PTT. Early objective assessment of a block can improve efficacy of operating room time and minimize patient's fear of possible conversion to general anesthesia. This study explores whether PTT can objectively, reliably and quickly predict a successful axillary block.
METHODS: Forty patients undergoing hand surgery under axillary block were included. A three-lead ECG and photoplethysmographic sensors were placed on both index fingers. Measurements were made from 2 min before until 30 min after induction of the block or less if the patient was transferred for operation. Afterwards, PTT was calculated as the time between the R-wave on ECG and a reference point on the photoplethysmogram. To assess the change in PTT caused by the block, the PTT difference between the control and blocked arm was calculated. Sensitivity and specificity of PTT difference were calculated using receiver operating characteristic analysis.
RESULTS: In a successful block, the mean PTT difference significantly increased after 3 min by 12 (standard error of the mean 3.9) ms, sensitivity 87% and specificity 71% (area under the curve 0.87, P = 0.004).
CONCLUSIONS: PTT is a reliable, quick and objective method to assess whether axillary block is going to be successful or not.
© 2012 The Authors. Acta Anaesthesiologica Scandinavica © 2012 The Acta Anaesthesiologica Scandinavica Foundation.

Entities:  

Mesh:

Year:  2012        PMID: 22845715     DOI: 10.1111/j.1399-6576.2012.02746.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  7 in total

1.  The prolongation of pulse transit time after a stellate ganglion block: An objective indicator of successful block.

Authors:  Young Uk Kim; Yuseon Cheong; Yu Gyeong Kong; Jonghyuk Lee; Sehun Kim; Hong Gyu Choi; Jeong Hun Suh
Journal:  Pain Res Manag       Date:  2015-09-15       Impact factor: 3.037

2.  Increasing accuracy of pulse transit time measurements by automated elimination of distorted photoplethysmography waves.

Authors:  Marit H N van Velzen; Arjo J Loeve; Sjoerd P Niehof; Egbert G Mik
Journal:  Med Biol Eng Comput       Date:  2017-03-30       Impact factor: 2.602

3.  Change in pulse transit time in the lower extremity after lumbar sympathetic ganglion block: an early indicator of successful block.

Authors:  Eun-Young Joo; Yu Gyeong Kong; Jonghyuk Lee; Hyun-Seok Cho; Sung-Hoon Kim; Jeong Hun Suh
Journal:  J Int Med Res       Date:  2017-01-17       Impact factor: 1.671

4.  The key role of pulse wave transit time to predict blood pressure variation during anaesthesia induction.

Authors:  Guoqiang Hu; Minjuan Chen; Xiaodan Wang; Lingyang Chen; Weijian Wang
Journal:  J Int Med Res       Date:  2021-11       Impact factor: 1.671

5.  Area Under the Curve of Finger Photoplethysmography as an Evaluation Measure for Sympathetic Activity During Lumbar Epidural Anaesthesia.

Authors:  Slobodan Mihaljevic; Milenko Bevanda; Kresimir Reiner; Krunoslav Sporcic; Ljiljana Mihaljevic; Marko Cacic
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-03-01

6.  Small intra-individual variability of the pre-ejection period justifies the use of pulse transit time as approximation of the vascular transit.

Authors:  Minke C Kortekaas; Marit H N van Velzen; Frank Grüne; Sjoerd P Niehof; Robert J Stolker; Frank J P M Huygen
Journal:  PLoS One       Date:  2018-10-10       Impact factor: 3.240

Review 7.  Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review.

Authors:  Malak Abdullah Almarshad; Md Saiful Islam; Saad Al-Ahmadi; Ahmed S BaHammam
Journal:  Healthcare (Basel)       Date:  2022-03-16
  7 in total