Literature DB >> 22844044

The sensitivity, specificity and predictive values of raised plasma metal ion levels in the diagnosis of adverse reaction to metal debris in symptomatic patients with a metal-on-metal arthroplasty of the hip.

I A Malek1, A King, H Sharma, S Malek, K Lyons, S Jones, A John.   

Abstract

Plasma levels of cobalt and chromium ions and Metal Artefact Reduction Sequence (MARS)-MRI scans were performed on patients with 209 consecutive, unilateral, symptomatic metal-on-metal (MoM) hip arthroplasties. There was wide variation in plasma cobalt and chromium levels, and MARS-MRI scans were positive for adverse reaction to metal debris (ARMD) in 84 hips (40%). There was a significant difference in the median plasma cobalt and chromium levels between those with positive and negative MARS-MRI scans (p < 0.001). Compared with MARS-MRI as the potential reference standard for the diagnosis of ARMD, the sensitivity of metal ion analysis for cobalt or chromium with a cut-off of > 7 µg/l was 57%. The specificity was 65%, positive predictive value was 52% and the negative predictive value was 69% in symptomatic patients. A lowered threshold of > 3.5 µg/l for cobalt and chromium ion levels improved the sensitivity and negative predictive value to 86% and 74% but at the expense of specificity (27%) and positive predictive value (44%). Metal ion analysis is not recommended as a sole indirect screening test in the surveillance of symptomatic patients with a MoM arthroplasty. The investigating clinicians should have a low threshold for obtaining cross-sectional imaging in these patients, even in the presence of low plasma metal ion levels.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22844044     DOI: 10.1302/0301-620X.94B8.27626

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  21 in total

1.  Heavy metal? Recognizing complications of metal on metal hip arthroplasty.

Authors:  Denise M Millstine; Hannah J Hakes; Anita P Mayer; Mark J Spangehl
Journal:  J Womens Health (Larchmt)       Date:  2014-06-16       Impact factor: 2.681

2.  Influence of implant design on blood metal ion concentrations in metal-on-metal total hip replacement patients.

Authors:  Gulraj S Matharu; Fiona Berryman; Lesley Brash; Paul B Pynsent; Ronan B Treacy; David J Dunlop
Journal:  Int Orthop       Date:  2015-02-06       Impact factor: 3.075

3.  601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.

Authors:  Amit Atrey; Alister Hart; Nasir Hussain; Jonathon Waite; Andrew J Shepherd; Steve Young
Journal:  J Orthop       Date:  2016-10-31

4.  What are the predictors and prevalence of pseudotumor and elevated metal ions after large-diameter metal-on-metal THA?

Authors:  Nick Bayley; Habeeb Khan; Paul Grosso; Thomas Hupel; David Stevens; Matthew Snider; Emil Schemitsch; Paul Kuzyk
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

5.  What causes unexplained pain in patients with metal-on metal hip devices? A retrieval, histologic, and imaging analysis.

Authors:  Danyal H Nawabi; Nader A Nassif; Huong T Do; Kirsten Stoner; Marcella Elpers; Edwin P Su; Timothy Wright; Hollis G Potter; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

6.  [MRI investigations in patients with problems due to metal-on-metal implants].

Authors:  T M Parsons; K Satchithananda; R Berbe; I A Siddiqui; E Robinson; A J Hart; A Hart
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

7.  [Update on metal-on-metal hip joints].

Authors:  K-P Günther; J Lützner; F Hannemann; J Schmitt; S Kirschner; J Goronzy; M Stiehler; C Lohmann; A Hartmann
Journal:  Orthopade       Date:  2013-05       Impact factor: 1.087

8.  [Metal ion concentrations in patients with metal-metal bearings in prostheses].

Authors:  J P Kretzer; C Van Der Straeten; R Sonntag; U Müller; M Streit; B Moradi; S Jäger; J Reinders
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

9.  Outcome of revision surgery for adverse local tissue reactions in patients with recalled total hip arthroplasty.

Authors:  Christian Klemt; Sakkadech Limmahakhun; Georges Bounajem; Christopher M Melnic; Michael J Harvey; Young-Min Kwon
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-09       Impact factor: 2.928

10.  The Interchangeability of Plasma and Whole Blood Metal Ion Measurement in the Monitoring of Metal on Metal Hips.

Authors:  Ibrahim A Malek; Joanne Rogers; Amanda Christina King; Juliet Clutton; Daniel Winson; Alun John
Journal:  Arthritis       Date:  2015-12-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.