In this work, a reliable methodology for the simultaneous analysis of PCDD/PCDF and dioxin-like PCB (dl-PCB) in flue gas emissions collected using continuous sampling devices is proposed. The analytical scheme followed the minimum requirements described in the EU standard EN-1948:1,2,3,4 according to samples containing large amounts of dioxins and dl-PCBs or samples collected over a long period of time of about 4 weeks. Parameters, such as reproducibility, precision, limits of detection (LOD), limits of quantification (LOQ), extract aliquot size, analytical blanks, extraction efficiency, as well as the amount of internal standards required for an accurate determination, were assessed. The findings demonstrate the suitability of the proposed analytical scheme for the analysis of PCDD/PCDF and PCB in samples collected using long-term sampling devices. The analysis of five different 5% v/v sample aliquots reported %RSD values lower than 10% for all of the 29 congeners at both low and high levels. Similarly, %RSD values were 3.2 and 2.0 for the low level samples and 0.9 and 1.1%RSD for the high level extracts for PCDD/PCDF and dl-PCB, respectively expressed in total TEQ units. Re-extraction provided values less than 3%, expressed in TEQ. Based on blank analyses, LOD values of 100 pg I-TEQ for PCDD/PCDF and 10 pg WHO-TEQ for dl-PCB were achieved when 5% v/v aliquots were analyzed. Finally, the proposed analytical approach was tested with samples from a wide range of combustion processes such as hazardous and municipal waste incinerators, as well as cement kilns (with and without waste co-incineration).
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22842592     DOI: 10.1016/j.scitotenv.2012.06.099

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  2 in total

1.  Effects of bypass system on PCDD/F emission and chlorine circulation in cement kilns.

Authors:  Ming-Xiu Zhan; Jianying Fu; Tong Chen; Yeqing Li; Jiang Zhang; Xiao-Dong Li; Jian-Hua Yan; Alfons Buekens
Journal:  Environ Sci Pollut Res Int       Date:  2016-07-10       Impact factor: 4.223

2.  Emission and distribution of PCDD/Fs and CBzs from two co-processing RDF cement plants in China.

Authors:  Tong Chen; Ming-Xiu Zhan; Xiao-Qing Lin; Ye-Qing Li; Jiang Zhang; Xiao-Dong Li; Jian-Hua Yan; Alfons Buekens
Journal:  Environ Sci Pollut Res Int       Date:  2016-03-09       Impact factor: 4.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.