Literature DB >> 22842036

Influence of the fiber diameter and surface roughness of electrospun vascular grafts on blood activation.

Vincent Milleret1, Thomas Hefti, Heike Hall, Viola Vogel, Daniel Eberli.   

Abstract

Electrospun grafts have been widely investigated for vascular graft replacement due to their ease and compatibility with many natural and synthetic polymers. Here, the effect of the processing parameters on the scaffold's architecture and subsequent reactions of partially heparinized blood triggered by contacting these topographies were studied. Degrapol® (DP) and poly(lactic-co-glycolic acid) (PLGA) electrospun fibrous scaffolds were characterized with regard to fiber diameter, pore area and scaffold roughness. The study showed that electrospinning parameters greatly affect fiber diameter together with pore dimension and overall scaffold roughness. Coagulation cascade activation, early platelet adhesion and activation were analyzed after 2h of exposure of blood to the biomaterials. While no differences were found between DP and PLGA with similar topographies, the blood reactions were observed to be dependent on the fiber diameter and scaffold roughness. Scaffolds composed of thin fibers (diameter <1μm) triggered very low coagulation and almost no platelets adhered. On the other hand, scaffolds with a bigger fiber diameter (2-3μm) triggered higher thrombin formation and more platelets adhered. The highest platelet adhesion and activations rates as well as coagulation cascade activation were found in blood incubated in contact with the scaffolds produced with the biggest fiber diameter (5μm). These findings indicate that electrospun grafts with small fiber diameter (<1μm) could perform better with reduced early thrombogenicity due to lower platelet adhesion and lower activation of platelets and coagulation cascade.
Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22842036     DOI: 10.1016/j.actbio.2012.07.032

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  27 in total

Review 1.  Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Authors:  Daniel Radke; Wenkai Jia; Dhavan Sharma; Kemin Fena; Guifang Wang; Jeremy Goldman; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2018-05-07       Impact factor: 9.933

2.  Hemocompatibility of Poly(vinyl alcohol)-Gelatin Core-Shell Electrospun Nanofibers: A Scaffold for Modulating Platelet Deposition and Activation.

Authors:  Valerie M Merkle; Daniel Martin; Marcus Hutchinson; Phat L Tran; Alana Behrens; Samir Hossainy; Jawaad Sheriff; Danny Bluestein; Xiaoyi Wu; Marvin J Slepian
Journal:  ACS Appl Mater Interfaces       Date:  2015-04-08       Impact factor: 9.229

3.  From arteries to capillaries: approaches to engineering human vasculature.

Authors:  Sharon Fleischer; Daniel Naveed Tavakol; Gordana Vunjak-Novakovic
Journal:  Adv Funct Mater       Date:  2020-06-11       Impact factor: 18.808

Review 4.  Mesenchymal stem cell cultivation in electrospun scaffolds: mechanistic modeling for tissue engineering.

Authors:  Ágata Paim; Isabel C Tessaro; Nilo S M Cardozo; Patricia Pranke
Journal:  J Biol Phys       Date:  2018-03-05       Impact factor: 1.365

5.  Novel Bioresorbable Vascular Graft With Sponge-Type Scaffold as a Small-Diameter Arterial Graft.

Authors:  Tadahisa Sugiura; Shuhei Tara; Hidetaka Nakayama; Hirotsugu Kurobe; Tai Yi; Yong-Ung Lee; Avione Y Lee; Christopher K Breuer; Toshiharu Shinoka
Journal:  Ann Thorac Surg       Date:  2016-05-04       Impact factor: 4.330

6.  Tissue-Engineered Heart Valves: A Call for Mechanistic Studies.

Authors:  Kevin M Blum; Joseph D Drews; Christopher K Breuer
Journal:  Tissue Eng Part B Rev       Date:  2018-02-13       Impact factor: 6.389

7.  Electrospun polyurethane nanofibrous composite impregnated with metallic copper for wound-healing application.

Authors:  Saravana Kumar Jaganathan; Mohan Prasath Mani
Journal:  3 Biotech       Date:  2018-07-18       Impact factor: 2.406

8.  Active wrinkles to drive self-cleaning: A strategy for anti-thrombotic surfaces for vascular grafts.

Authors:  Luka Pocivavsek; Sang-Ho Ye; Joseph Pugar; Edith Tzeng; Enrique Cerda; Sachin Velankar; William R Wagner
Journal:  Biomaterials       Date:  2018-11-05       Impact factor: 12.479

9.  Electrospun Tissue-Engineered Arterial Graft Thickness Affects Long-Term Composition and Mechanics.

Authors:  Yen-Lin Wu; Jason M Szafron; Kevin M Blum; Jacob C Zbinden; Ramak Khosravi; Cameron A Best; James W Reinhardt; Qiang Zeng; Tai Yi; Toshiharu Shinoka; Jay D Humphrey; Christopher K Breuer; Yadong Wang
Journal:  Tissue Eng Part A       Date:  2020-09-30       Impact factor: 3.845

10.  In vitro and ex vivo hemocompatibility of off-the-shelf modified poly(vinyl alcohol) vascular grafts.

Authors:  Marie F A Cutiongco; Deirdre E J Anderson; Monica T Hinds; Evelyn K F Yim
Journal:  Acta Biomater       Date:  2015-07-27       Impact factor: 8.947

View more