Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

Gyeong Suk Ryu1, Yu Jeung Lee.   

Abstract

BACKGROUND: Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices.
OBJECTIVE: To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy.
METHODS: Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended.
RESULTS: Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4.660 mL for the dosing spoon (n = 10; P < 0.001). Doses were within 10% of the 5 mL target volume for 88.7% (n = 266) of the participant samples. Only 34 cases (11.3%) had dose errors greater than 10%, and only 6 cases (2.0%) had a variance of more than 20% from the 5 mL target volume. Dose errors greater than 10% of the target volume were more common for the etched dosing cup (47.1%, n = 8), the dosing spoon (50.0%, n = 5), and the printed dosing cup (30.8%, n = 4), but these 3 devices were used by only 13.3% of the study participants.
CONCLUSIONS: Approximately 1 in 10 participants measured doses of liquid medication with a volume error greater than 10%, and these dose errors were more common with the etched dosing cup, the dosing spoon, and the printed dosing cup. Pharmacists have an opportunity to counsel patients or caregivers regarding the appropriate use of measuring devices for liquid medication.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22839684     DOI: 10.18553/jmcp.2012.18.6.439

Source DB:  PubMed          Journal:  J Manag Care Pharm        ISSN: 1083-4087


  9 in total

1.  Liquid Drug Dosage Measurement Errors with Different Dosing Devices.

Authors:  Pradnya Joshi; Sandeep B Bavdekar
Journal:  Indian J Pediatr       Date:  2019-02-28       Impact factor: 1.967

2.  Ability of Saudi mothers to appropriately and accurately use dosing devices to administer oral liquid medications to their children.

Authors:  Saja Almazrou; Hind Alsahly; Huda Alwattar; Lamya Alturki; Mona Alamri
Journal:  Drug Healthc Patient Saf       Date:  2014-12-22

Review 3.  Carers' Medication Administration Errors in the Domiciliary Setting: A Systematic Review.

Authors:  Anam Parand; Sara Garfield; Charles Vincent; Bryony Dean Franklin
Journal:  PLoS One       Date:  2016-12-01       Impact factor: 3.240

4.  Dosing Accuracy of Oral Extemporaneous Suspensions of Antibiotics: Measuring Procedures and Administration Devices.

Authors:  Inês Neves; Maria D Auxtero
Journal:  Pharmaceutics       Date:  2021-04-10       Impact factor: 6.321

5.  Considerations over a Case of Suspected Therapeutic Failure in Pediatric Patients after Switching Valproate Manufacturers.

Authors:  Jaqueline Kalleian Eserian; Jair Ribeiro Chagas; José Carlos Fernandes Galduróz
Journal:  Innov Pharm       Date:  2020-07-31

6.  Drug-handling problems and expectations of the ideal pediatric drug-reported by children and their parents.

Authors:  Birthe Herziger; Sarah Jeschke; Ruth Melinda Müller; Martina Patrizia Neininger; Thilo Bertsche; Astrid Bertsche
Journal:  Eur J Pediatr       Date:  2022-02-23       Impact factor: 3.860

7.  Can use of pictograms reduce liquid medication administration errors by mothers? An interventional study.

Authors:  Pawan Patidar; Aditya Mathur; Ashish Pathak
Journal:  BMC Psychol       Date:  2021-06-25

Review 8.  Drug safety: The concept, inception and its importance in patients' health.

Authors:  Thamir M Alshammari
Journal:  Saudi Pharm J       Date:  2014-05-09       Impact factor: 4.330

9.  A study of knowledge, attitude and practice regarding administration of pediatric dosage forms and allied health literacy of caregivers for children.

Authors:  Amrita Sil; Chaitali Sengupta; Alak Kumar Das; Puspita Das Sil; Supratim Datta; Avijit Hazra
Journal:  J Family Med Prim Care       Date:  2017 Jul-Sep
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.