Literature DB >> 22836079

Comparative study of Newtonian and non-Newtonian simulations of drug transport in a model drug-eluting stent.

Zhenze Wang1, Anqiang Sun, Yubo Fan, Xiaoyan Deng.   

Abstract

To elucidate the difference between Newtonian and shear thinning non-Newtonian assumptions of blood in the analysis of DES drug delivery, we numerically simulated the local flow pattern and the concentration distribution of the drug at the lumen-tissue interface for a structurally simplified DES deployed in a curved segment of an artery under pulsatile blood flow conditions. The numerical results showed that when compared with the Newtonian model, the Carreau (shear thinning) model could lead to some differences in the luminal surface drug concentration in certain areas along the outer wall of the curved vessel. In most areas of the vessel, however, there were no significant differences between the 2 models. Particularly, no significant difference between the two models was found in terms of the area-averaged luminal surface drug concentration. Therefore, we believe that the shear thinning property of blood may play little roles in DES drug delivery. Nevertheless, before we draw the conclusion that Newtonian assumption of blood can be used to replace its non-Newtonian one for the numerical simulation of drug transport in the DES implanted coronary artery, other more complex mechanical properties of blood such as its thixotropic behavior should be tested.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22836079     DOI: 10.3233/BIR-2012-0607

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  6 in total

1.  A finite element study on variations in mass transport in stented porcine coronary arteries based on location in the coronary arterial tree.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

2.  Hemodynamic Parameters Predict In-stent Thrombosis After Multibranched Endovascular Repair of Complex Abdominal Aortic Aneurysms: A Retrospective Study of Branched Stent-Graft Thrombosis.

Authors:  Ming-Yuan Liu; Yang Jiao; Junjun Liu; Simeng Zhang; Wei Li
Journal:  Front Cardiovasc Med       Date:  2021-04-23

3.  Does lower limb exercise worsen renal artery hemodynamics in patients with abdominal aortic aneurysm?

Authors:  Anqiang Sun; Xiaopeng Tian; Nan Zhang; Zaipin Xu; Xiaoyan Deng; Ming Liu; Xiao Liu
Journal:  PLoS One       Date:  2015-05-06       Impact factor: 3.240

4.  Influence of Artery Straightening on Local Hemodynamics in Left Anterior Descending (LAD) Artery after Stent Implantation.

Authors:  Pengfei Liu; Xiaoyan Deng; Xiao Liu; Anqiang Sun; Hongyan Kang
Journal:  Cardiol Res Pract       Date:  2020-05-22       Impact factor: 1.866

5.  Three-dimensional ophthalmic artery model reconstruction and assessment captured by computed tomographic angiography in non-arteritic anterior ischemic optic neuropathy patients.

Authors:  Jia-Lin Wang; Dong-Hui Wu; Hong-Yang Li; Yan-Ling Wang
Journal:  Ann Transl Med       Date:  2021-03

6.  Gender differences of morphological and hemodynamic characteristics of abdominal aortic aneurysm.

Authors:  Zujie Gao; Jiang Xiong; Zengsheng Chen; Xiaoyan Deng; Zaipin Xu; Anqiang Sun; Yubo Fan
Journal:  Biol Sex Differ       Date:  2020-07-21       Impact factor: 5.027

  6 in total