Literature DB >> 22834720

A randomized controlled trial of the effect of intrapartum intravenous fluid management on breastfed newborn weight loss.

Jo Watson1, Ellen Hodnett2, B Anthony Armson3, Barbara Davies4, Judy Watt-Watson5.   

Abstract

OBJECTIVE: To determine the effect of conservative versus usual intrapartum intravenous (IV) fluid management for low-risk women receiving epidural analgesia on weight loss in breastfed newborns.
DESIGN: A randomized controlled trial.
SETTING: A tertiary perinatal center in a large urban setting. SAMPLE: Women experiencing uncomplicated pregnancies who planned to have epidural analgesia and to breastfeed.
METHODS: Healthy pregnant women were randomized to receive an IV epidural preload volume of <500 mLs continuing at an hourly rate of 75-100 mL/h (conservative care) or an epidural preload volume of ≥500 mLs and an hourly rate >125 mL/h (usual care). The primary study outcome was breastfed newborn weight loss >7% prior to hospital discharge. Secondary study outcomes included breastfeeding exclusivity, referral to outpatient breastfeeding clinic support, and delayed discharge. Other outcomes were admission to the neonatal intensive care unit and cord blood pH <7.25.
RESULTS: Two hundred women participated (100 in the conservative care and 100 in the usual care groups). Forty-eight of 100 infants in the usual care group and 44 of the 100 infants in the conservative care group lost >7% of their birth weight prior to discharge, p < 0.52 RR 0.92 [0.68-1.24].
CONCLUSION: A policy of restricted IV fluids did not affect newborn weight loss. Women and their care providers should be reassured that the volumes of IV fluid <2500 mLs are unlikely to have a clinically meaningful effect on breastfed newborn weight loss >7%. Exploratory analyses suggest that breastfed newborn weight loss increases when intrapartum volumes infused are >2500 mLs. Care providers are encouraged to consider volumes of IV fluid infused intrapartum as a factor that may have contributed to early newborn weight loss in the first 48 h of life.
© 2012 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22834720     DOI: 10.1111/j.1552-6909.2011.01321.x

Source DB:  PubMed          Journal:  J Obstet Gynecol Neonatal Nurs        ISSN: 0090-0311


  6 in total

1.  Early weight loss nomograms for exclusively breastfed newborns.

Authors:  Valerie J Flaherman; Eric W Schaefer; Michael W Kuzniewicz; Sherian X Li; Eileen M Walsh; Ian M Paul
Journal:  Pediatrics       Date:  2014-12-01       Impact factor: 7.124

2.  Relationship of newborn weight loss to milk supply concern and anxiety: the impact on breastfeeding duration.

Authors:  Valerie J Flaherman; Jessica S Beiler; Michael D Cabana; Ian M Paul
Journal:  Matern Child Nutr       Date:  2015-03-18       Impact factor: 3.092

3.  Neonatal Readmissions to a Level 4 Hospital.

Authors:  Olivia Jarrett; Wafa Kulsoom Khan; Anthony Liu; Habib Bhurawala
Journal:  J Paediatr Child Health       Date:  2022-06-20       Impact factor: 1.929

4.  Excessive weight loss in exclusively breastfed full-term newborns in a Baby-Friendly Hospital.

Authors:  Maria Aparecida Mezzacappa; Bruna Gil Ferreira
Journal:  Rev Paul Pediatr       Date:  2016-01-06

5.  Intrapartum intravenous fluids for caesarean delivery and newborn weight loss: a retrospective cohort study.

Authors:  Sherif Eltonsy; Alain Blinn; Brigitte Sonier; Steven DeRoche; Aubin Mulaja; William Hynes; André Barrieau; Mathieu Belanger
Journal:  BMJ Paediatr Open       Date:  2017-08-11

6.  Copeptin Concentrations in Plasma of Healthy Neonates in Relation to Water-Electrolyte Homeostasis in the Early Adaptation Period.

Authors:  Anna Jarosz-Lesz; Aniceta Brzozowska; Iwona Maruniak-Chudek
Journal:  Children (Basel)       Date:  2022-03-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.