| Literature DB >> 2283378 |
K Matsubayashi1, M Yoshioka, H Tachizawa.
Abstract
A sensitive method for the determination of DQ-2556 by high-performance liquid chromatography was established. The limits of detection for serum and urine were 0.1 and 2 micrograms/ml, respectively. Two clean-up procedures for serum samples were developed. In the first, deproteinization with 10% trichloroacetic acid was used and the recovery was 68.5%. In the other, ultrafiltration under acidic conditions was employed and the recovery was 85.1%. The former procedure is economical but complicated, whereas the latter is simple and labour-saving, but a special ultrafiltration tube is required. This situation offers a flexible choice, depending on the conditions of the laboratory.Entities:
Mesh:
Substances:
Year: 1990 PMID: 2283378 DOI: 10.1016/s0021-9673(01)89353-5
Source DB: PubMed Journal: J Chromatogr