Literature DB >> 22833318

Comparison study and thoron interference test of different radon monitors.

C G Sumesh1, A Vinod Kumar, R M Tripathi, V D Puranik.   

Abstract

A comparison study and thoron interference test for different continuous radon monitors were carried out. The comparison study includes three passive diffusion monitors [one pulse ionisation chamber based-Alpha Guard and two silicon semi-conductor based-Radon Scout Plus (RSP)] and one silicon semi-conductor-based active radon thoron discriminating monitor--RAD 7. Radon emanation standard, supplied by National Institute of Science and Technology, has been utilised for the comparison study to qualify the calibration of the continuous radon monitors. All the instruments showed good agreement with the estimated radon concentration using (226)Ra/(222)Rn emanation standard. It was found that the active radon monitoring system is having a higher initial response towards the transient radon concentration than the passive radon monitors studied. The instruments measuring radon concentration without energy discrimination are likely to have some sensitivity towards the thoron concentration. Thus, thoron interference study was carried out in the above monitors. Nine percent interference in measured radon concentration in the Alpha Guard monitor and 4 % interference in the semi-conductor-based RSP monitors was observed. Study indicates that the interference of thoron in radon monitors depends on the area of diffusion of gas, volume of detection and sensitivity factor.

Mesh:

Substances:

Year:  2012        PMID: 22833318     DOI: 10.1093/rpd/ncs118

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Comparison of results from indoor radon measurements using active and passive methods with those from mathematical modeling.

Authors:  A K Visnuprasad; K E Reby Roy; P J Jojo; B K Sahoo
Journal:  Radiat Environ Biophys       Date:  2019-06-27       Impact factor: 1.925

2.  Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air.

Authors:  Yasutaka Omori; Michikuni Shimo; Miroslaw Janik; Tetsuo Ishikawa; Hidenori Yonehara
Journal:  Int J Environ Res Public Health       Date:  2020-02-04       Impact factor: 3.390

3.  Thoron Interference on Performance of Continuous Radon Monitors: An Experimental Study on Four Devices and a Proposal of an Indirect Method to Estimate Thoron Concentration.

Authors:  Christian Di Carlo; Marco Ampollini; Sara Antignani; Mario Caprio; Carmela Carpentieri; Francesco Bochicchio
Journal:  Int J Environ Res Public Health       Date:  2022-02-19       Impact factor: 3.390

4.  Impact of Wind Speed on Response of Diffusion-Type Radon-Thoron Detectors to Thoron.

Authors:  Yasutaka Omori; Yuki Tamakuma; Eka Djatnika Nugraha; Takahito Suzuki; Miki Arian Saputra; Masahiro Hosoda; Shinji Tokonami
Journal:  Int J Environ Res Public Health       Date:  2020-05-02       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.