Literature DB >> 22832674

Novel assessment of temporal variation in fractionated electrograms using histogram analysis of local fractionation interval in patients with persistent atrial fibrillation.

Yenn-Jiang Lin1, Kazuyoshi Suenari, Men-Tzung Lo, Chen Lin, Wan-Hsin Hsieh, Shih-Lin Chang, Li-Wei Lo, Yu-Feng Hu, Chen-Chuan Cheng, Yasuki Kihara, Tze-Fan Chao, Beny Hartono, Tsu-Juey Wu, Wei-Shiang Lin, Ke-Hsin Hsu, Ambrose S Kibos, Norden E Huang, Shih-Ann Chen.   

Abstract

BACKGROUND: The characteristics of atrial electrograms associated with atrial fibrillation (AF) termination are controversial. We investigated the electrogram characteristics that indicate procedural AF termination during continuous complex fractionated electrogram ablation. METHODS AND
RESULTS: Fifty-two consecutive patients with persistent AF (47 men; aged 54 ± 9 years), who underwent electrogram-based catheter ablation in the left atrium and coronary sinus after pulmonary vein isolation, were enrolled. The intracardiac bipolar atrial electrogram recordings were characterized by (1) fractionation interval (FI) analysis (>6 seconds), (2) kurtosis (shape of the FI histogram), and (3) skewness (asymmetry of the FI histogram). Sites showing complex, fractionated electrograms (mean FI ≤ 60 ms) were targeted, and AF was terminated in 20 patients (38%) after the pulmonary vein isolation. The conventional complex fractionated electrogram sites (mean ≤ 120 ms) in patients with AF termination exhibited higher median kurtosis (2.69 [interquartile range, 2.03-3.46] versus 2.35 [interquartile range, 1.79-2.48]; P=0.024) and higher complex fractionated electrogram-mean interval (102.7 ± 19.8 versus 87.7 ± 15.0; P=0.008) than patients without AF termination. Furthermore, AF termination sites had higher median kurtosis than targeted sites without AF termination (5.13 [interquartile range, 3.51-6.47] versus 4.18 [interquartile range, 2.91-5.34]; P<0.01) in patients with procedural termination. In addition, patients with AF termination had a higher sinus rhythm maintenance rate after a single procedure than patients without AF termination (log-rank test, P=0.007).
CONCLUSIONS: A kurtosis analysis using the FI histogram may be a useful tool in identifying the critical substrate for persistent AF and potential responders to catheter ablation.

Entities:  

Mesh:

Year:  2012        PMID: 22832674     DOI: 10.1161/CIRCEP.111.967612

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  2 in total

1.  Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study.

Authors:  Serge Boveda; Rui Providência; Pascal Defaye; Dominique Pavin; Jean-Pierre Cebron; Frederic Anselme; Franck Halimi; Ziad Khoueiry; Nicolas Combes; Stephane Combes; Sophie Jacob; Jean-Paul Albenque; Pedro Sousa
Journal:  J Interv Card Electrophysiol       Date:  2016-05-18       Impact factor: 1.900

2.  Usefulness of HATCH score in the prediction of new-onset atrial fibrillation for Asians.

Authors:  Kazuyoshi Suenari; Tze-Fan Chao; Chia-Jen Liu; Yasuki Kihara; Tzeng-Ji Chen; Shih-Ann Chen
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.