Literature DB >> 22832507

A new strategy for the detection of adenosine triphosphate by aptamer/quantum dot biosensor based on chemiluminescence resonance energy transfer.

Zi-Ming Zhou1, Yong Yu, Yuan-Di Zhao.   

Abstract

We designed an aptasensor for the detection of adenosine triphosphate (ATP) based on chemiluminescence resonance energy transfer (CRET). An adenosine aptamer was cut into two pieces of ssDNA, which were attached to quantum dots (QDs) and horse radish peroxidase (HRP), respectively. They could reassemble into specific structures in the presence of ATP and then decrease the distance of HRP and QDs. ATP detection can be easily realized according to the fluorescent intensity of QDs, which is excited by CRET between luminol and QDs. Results show that the concentration of ATP is linear relation with the fluorescent intensity of the peak of QDs emission and the linear range for the linear equation is from 50 μM to 231 μM and the detection limit was 185 nM. When the concentration of ATP was 2 mM, the efficiency of CRET is 13.6%. Good specificity for ATP had been demonstrated compared to thymidine triphosphate (TTP), cytidine triphosphate (CTP) and guanosine triphosphate (GTP), when 1 mM of each was added, respectively. This method needs no external light source and can avoid autofluorescence and photobleaching, and ATP can be detected selectively, specifically, and sensitively in a low micromolar range, which means that the strategy reported here can be applicable to the detection of several other target molecules.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22832507     DOI: 10.1039/c2an35520e

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

Review 1.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

2.  A multifunctional probe based on the use of labeled aptamer and magnetic nanoparticles for fluorometric determination of adenosine 5'-triphosphate.

Authors:  Xiaojie Liu; Bixia Lin; Ying Yu; Yujuan Cao; Manli Guo
Journal:  Mikrochim Acta       Date:  2018-04-02       Impact factor: 5.833

Review 3.  Optical Aptasensors for Adenosine Triphosphate.

Authors:  Stella Ng; Hui Si Lim; Qian Ma; Zhiqiang Gao
Journal:  Theranostics       Date:  2016-06-21       Impact factor: 11.556

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.