Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses.

Kelsey A Potter1, Amy C Buck, Wade K Self, Jeffrey R Capadona.   

Abstract

An estimated 25 million people in the US alone rely on implanted medical devices, ∼2.5 million implanted within the nervous system. Even though many devices perform adequately for years, the host response to medical devices often severely limits tissue integration and long-term performance. This host response is believed to be particularly limiting in the case of intracortical microelectrodes, where it has been shown that glial cell encapsulation and localized neuronal cell loss accompany intracortical microelectrode implantation. Since neuronal ensembles must be within ∼50 µm of the electrode to obtain neuronal spikes and local field potentials, developing a better understanding of the molecular and cellular environment at the device-tissue interface has been the subject of significant research. Unfortunately, immunohistochemical studies of scar maturation in correlation to device function have been inconclusive. Therefore, here we present a detailed quantitative study of the cellular events and the stability of the blood-brain barrier (BBB) following intracortical microelectrode implantation and cortical stab injury in a chronic survival model. We found two distinctly inverse multiphasic profiles for neuronal survival in device-implanted tissue compared to stab-injured animals. For chronically implanted animals, we observed a biphasic paradigm between blood-derived/trauma-induced and CNS-derived inflammatory markers driving neurodegeneration at the interface. In contrast, stab injured animals demonstrated a CNS-mediated neurodegenerative environment. Collectively these data provide valuable insight to the possibility of multiple roles of chronic neuroinflammatory events on BBB disruption and localized neurodegeneration, while also suggesting the importance to consider multiphasic neuroinflammatory kinetics in the design of therapeutic strategies for stabilizing neural interfaces.

Entities:  

Mesh:

Year:  2012        PMID: 22832283     DOI: 10.1088/1741-2560/9/4/046020

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  84 in total

1.  Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.

Authors:  Arati Sridharan; Jessica K Nguyen; Jeffrey R Capadona; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2015-04-02       Impact factor: 5.379

2.  Neuron-like neural probes.

Authors:  Jeffrey R Capadona; Andrew J Shoffstall; Joseph J Pancrazio
Journal:  Nat Mater       Date:  2019-05       Impact factor: 43.841

Review 3.  Understanding the Role of Innate Immunity in the Response to Intracortical Microelectrodes.

Authors:  John K Hermann; Jeffrey R Capadona
Journal:  Crit Rev Biomed Eng       Date:  2018

Review 4.  Physiological properties of brain-machine interface input signals.

Authors:  Marc W Slutzky; Robert D Flint
Journal:  J Neurophysiol       Date:  2017-06-14       Impact factor: 2.714

5.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

Review 6.  Brain Machine Interfaces for Vision Restoration: The Current State of Cortical Visual Prosthetics.

Authors:  Soroush Niketeghad; Nader Pouratian
Journal:  Neurotherapeutics       Date:  2019-01       Impact factor: 7.620

7.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

8.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

9.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

10.  Neuroadhesive protein coating improves the chronic performance of neuroelectronics in mouse brain.

Authors:  Asiyeh Golabchi; Kevin M Woeppel; Xia Li; Carl F Lagenaur; X Tracy Cui
Journal:  Biosens Bioelectron       Date:  2020-02-18       Impact factor: 10.618

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.