Literature DB >> 22832101

Feasibility of clinical magnetoencephalography (MEG) functional mapping in the presence of dental artefacts.

A Hillebrand1, P Fazio, J C de Munck, B W van Dijk.   

Abstract

OBJECTIVE: To evaluate the viability of MEG source reconstruction in the presence of large interference due to orthodontic material.
METHODS: We recorded the magnetic fields following a simple hand movement and following electrical stimulation of the median nerve (somatosensory evoked field -SEF). These two tasks were performed twice, once with and once without artificial dental artefacts. Temporal Signal Space Separation (tSSS) was applied to spatially filter the data and source reconstruction was performed according to standard procedures for pre-surgical mapping of eloquent cortex, applying dipole fitting to the SEF data and beamforming to the hand movement data.
RESULTS: Comparing the data with braces to the data without braces, the observed distances between the activations following hand movement in the two conditions were on average 6.4 and 4.5 mm for the left and right hand, respectively, whereas the dipole localisation errors for the SEF were 4.1 and 5.4 mm, respectively. Without tSSS it was generally not possible to obtain reliable dipole fit or beamforming results when wearing braces.
CONCLUSION: We confirm that tSSS is a required and effective pre-processing step for data recorded with the Elekta-MEG system. Moreover, we have shown that even the presence of large interference from orthodontic material does not significantly alter the results from dipole localisation or beamformer analysis, provided the data are spatially filtered by tSSS. SIGNIFICANCE: State-of-the-art signal processing techniques enable the use of MEG for pre-surgical evaluation in a much larger clinical population than previously thought possible.
Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22832101     DOI: 10.1016/j.clinph.2012.06.013

Source DB:  PubMed          Journal:  Clin Neurophysiol        ISSN: 1388-2457            Impact factor:   3.708


  17 in total

1.  MEG source imaging method using fast L1 minimum-norm and its applications to signals with brain noise and human resting-state source amplitude images.

Authors:  Ming-Xiong Huang; Charles W Huang; Ashley Robb; AnneMarie Angeles; Sharon L Nichols; Dewleen G Baker; Tao Song; Deborah L Harrington; Rebecca J Theilmann; Ramesh Srinivasan; David Heister; Mithun Diwakar; Jose M Canive; J Christopher Edgar; Yu-Han Chen; Zhengwei Ji; Max Shen; Fady El-Gabalawy; Michael Levy; Robert McLay; Jennifer Webb-Murphy; Thomas T Liu; Angela Drake; Roland R Lee
Journal:  Neuroimage       Date:  2013-09-19       Impact factor: 6.556

2.  What graph theory actually tells us about resting state interictal MEG epileptic activity.

Authors:  Guiomar Niso; Sira Carrasco; María Gudín; Fernando Maestú; Francisco Del-Pozo; Ernesto Pereda
Journal:  Neuroimage Clin       Date:  2015-05-23       Impact factor: 4.881

3.  Magnetoencephalographic study of hand and foot sensorimotor organization in 325 consecutive patients evaluated for tumor or epilepsy surgery.

Authors:  Ronald B Willemse; Arjan Hillebrand; Hanneke E Ronner; W Peter Vandertop; Cornelis J Stam
Journal:  Neuroimage Clin       Date:  2015-11-07       Impact factor: 4.881

4.  Choice of Magnetometers and Gradiometers after Signal Space Separation.

Authors:  Pilar Garcés; David López-Sanz; Fernando Maestú; Ernesto Pereda
Journal:  Sensors (Basel)       Date:  2017-12-16       Impact factor: 3.576

5.  Automated Detection of Epileptic Biomarkers in Resting-State Interictal MEG Data.

Authors:  Miguel C Soriano; Guiomar Niso; Jillian Clements; Silvia Ortín; Sira Carrasco; María Gudín; Claudio R Mirasso; Ernesto Pereda
Journal:  Front Neuroinform       Date:  2017-06-30       Impact factor: 4.081

6.  Functional cortical hubs in the eyes-closed resting human brain from an electrophysiological perspective using magnetoencephalography.

Authors:  Seung-Hyun Jin; Woorim Jeong; Jaeho Seol; Jiyeon Kwon; Chun Kee Chung
Journal:  PLoS One       Date:  2013-07-09       Impact factor: 3.240

7.  Localization of MEG pathologic gamma oscillations in adult epilepsy patients with focal cortical dysplasia.

Authors:  Woorim Jeong; June Sic Kim; Chun Kee Chung
Journal:  Neuroimage Clin       Date:  2013-10-02       Impact factor: 4.881

8.  Detecting a Cortical Fingerprint of Parkinson's Disease for Closed-Loop Neuromodulation.

Authors:  Kevin Kern; Georgios Naros; Christoph Braun; Daniel Weiss; Alireza Gharabaghi
Journal:  Front Neurosci       Date:  2016-03-30       Impact factor: 4.677

9.  Praxis-induced seizures in a patient with juvenile myoclonic epilepsy: MEG-EEG coregistration study.

Authors:  Sira Carrasco-García de León; Guiomar Niso; Leonidas Canuet; Laura Burriel-Lobo; Fernando Maestú; María Gudín Rodríguez-Magariños
Journal:  Epilepsy Behav Case Rep       Date:  2015-11-04

10.  Comparing the Performance of Popular MEG/EEG Artifact Correction Methods in an Evoked-Response Study.

Authors:  Niels Trusbak Haumann; Lauri Parkkonen; Marina Kliuchko; Peter Vuust; Elvira Brattico
Journal:  Comput Intell Neurosci       Date:  2016-07-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.