Literature DB >> 22828853

Large improvement of the electrical impedance of imaging and high-intensity focused ultrasound (HIFU) phased arrays using multilayer piezoelectric ceramics coupled in lateral mode.

Junho Song1, Benjamin Lucht, Kullervo Hynynen.   

Abstract

With a change in phased-array configuration from one dimension to two, the electrical impedance of the array elements is substantially increased because of their decreased width (w)-to-thickness (t) ratio. The most common way to compensate for this impedance increase is to employ electrical matching circuits at a high cost of fabrication complexity and effort. In this paper, we introduce a multilayer lateral-mode coupling method for phased-array construction. The direct comparison showed that the electrical impedance of a single-layer transducer driven in thickness mode is 1/(n²(1/(w/t))²) times that of an n-layer lateral mode transducer. A large reduction of the electrical impedance showed the impact and benefit of the lateral-mode coupling method. A one-dimensional linear 32-element 770-kHz imaging array and a 42-element 1.45-MHz high-intensity focused ultrasound (HIFU) phased array were fabricated. The averaged electrical impedances of each element were measured to be 58 Ω at the maximum phase angle of -1.2° for the imaging array and 105 Ω at 0° for the HIFU array. The imaging array had a center frequency of 770 kHz with an averaged -6-dB bandwidth of approximately 52%. For the HIFU array, the averaged maximum surface acoustic intensity was measured to be 32.8 W/cm² before failure.

Mesh:

Year:  2012        PMID: 22828853     DOI: 10.1109/TUFFC.2012.2358

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  3 in total

Review 1.  Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

Authors:  Kullervo Hynynen; Ryan M Jones
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

2.  HIFU Power Monitoring Using Combined Instantaneous Current and Voltage Measurement.

Authors:  Chris Adams; James R McLaughlan; Thomas M Carpenter; Steven Freear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-12       Impact factor: 2.725

3.  Real-time implementation of a dual-mode ultrasound array system: in vivo results.

Authors:  Andrew J Casper; Dalong Liu; John R Ballard; Emad S Ebbini
Journal:  IEEE Trans Biomed Eng       Date:  2013-05-21       Impact factor: 4.538

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.