Literature DB >> 22828008

Effects of a water-loading test on intraocular pressure and corneal hysteresis in young healthy subjects.

Fatih Ulaş1, Mehmet Balbaba, Serdal Celebi.   

Abstract

PURPOSE: To evaluate the influence of a water-loading test on corneal compensated intraocular pressure (IOPcc) and corneal hysteresis (CH) in young healthy subjects.
MATERIALS AND METHODS: Forty healthy adult subjects (20 female and 20 male), with a mean age of 27.55±2.57 years (range, 24 to 35 y), participated in this prospective study. IOPcc and CH were measured for 1 eye from each participant with an Ocular Response Analyser. These measurements were taken before and 10, 20, and 30 minutes after water loading.
RESULTS: Thirty-seven right and 3 left eyes of the 40 subjects fulfilled the study's inclusion criteria. A statistically significant increase in IOPcc was observed between 0 and 10 minutes (P=0.002) and a significant decrease between 10 and 30 minutes (P<0.001). We did not observe any statistically significant changes in CH. The Pearson correlation revealed that there was a weak negative correlation between IOPcc and CH measurements taken at the baseline, 10 minutes, and 30 minutes [r values were -0.275 (P=0.086), -0.369 (P=0.019), and -0.246 (P=0.125), respectively].
CONCLUSIONS: This study revealed changes in IOPcc and CH after a water-loading test, but only the change in the IOPcc measurement was statistically significant. The association of changes in IOP and CH identified in this study suggests that IOP changes might alter corneal biomechanical properties.

Entities:  

Mesh:

Year:  2014        PMID: 22828008     DOI: 10.1097/IJG.0b013e318264ce7c

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  5 in total

1.  Effects of water drinking test on ocular blood flow waveform parameters: A laser speckle flowgraphy study.

Authors:  Mehwish Saba Bhatti; Tong Boon Tang; Augustinus Laude
Journal:  PLoS One       Date:  2017-07-24       Impact factor: 3.240

2.  Intraocular Pressure and Corneal Biomechanical Changes after Water-Drinking Test in Glaucoma Patients.

Authors:  Farideh Sharifipour; Mohammad Malekahmadi; Mehdi Azimi; Bahman Cheraghian
Journal:  J Curr Ophthalmol       Date:  2022-01-06

3.  Short-Time Changes of Intraocular Pressure and Biomechanics of the Anterior Segment of the Eye during Water Drinking Test in Patients with XEN GelStent.

Authors:  Joanna Przeździecka-Dołyk; Ewa Wałek; Agnieszka Jóźwik; Iwona Helemejko; Magdalena Asejczyk-Widlicka; Marta Misiuk-Hojło
Journal:  J Clin Med       Date:  2021-12-29       Impact factor: 4.241

4.  Effects of water drinking on corneal biomechanics: The association with intraocular pressure changes.

Authors:  Jesús Vera; Beatríz Redondo; Rubén Molina; Raimundo Jiménez
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

5.  Commentary: Water, water everywhere; alters eye when you drink.

Authors:  John D Akkara; Anju Kuriakose
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.