| Literature DB >> 22824623 |
Jungwoo Lee1, Jong Seob Jeong, K Kirk Shung.
Abstract
It has recently been demonstrated that it was possible to individually trap 70μm droplets flowing within a 500μm wide microfluidic channel by a 24MHz single element piezo-composite focused transducer. In order to further develop this non-invasive approach as a microfluidic particle manipulation tool of high precision, the trapping force needs to be calibrated to a known force, i.e., viscous drag force arising from the fluid flow in the channel. However, few calibration studies based on fluid viscosity have been carried out with focused acoustic beams for moving objects in microfluidic environments. In this paper, the acoustic trapping force (F(trapping)) and the trap stiffness (or compliance k) are experimentally determined for a streaming droplet in a microfluidic channel. F(trapping) is calibrated to viscous drag force produced from syringe pumps. Chebyshev-windowed chirp coded excitation sequences sweeping the frequency range from 18MHz to 30MHz is utilized to drive the transducer, enabling the beam transmission through the channel/fluid interface for interrogating the droplets inside the channel. The minimum force (F(min,trapping)) required for initially immobilizing drifting droplets is determined as a function of pulse repetition frequency (PRF), duty factor (DTF), and input voltage amplitude (V(in)) to the transducer. At PRF=0.1kHz and DTF=30%, F(min,trapping) is increased from 2.2nN for V(in)=22V(pp) to 3.8nN for V(in)=54V(pp). With a fixed V(in)=54V(pp) and DTF=30%, F(min,trapping) can be varied from 3.8nN at PRF=0.1kHz to 6.7nN at PRF=0.5kHz. These findings indicate that both higher driving voltage and more frequent beam transmission yield stronger traps for holding droplets in motion. The stiffness k can be estimated through linear regression by measuring the trapping force (F(trapping)) corresponding to the displacement (x) of a droplet from the trap center. By plotting F(trapping) - x curves for certain values of V(in) (22/38/54V(pp)) at DTF=10% and PRF=0.1kHz, k is measured to be 0.09, 0.14, and 0.20nN/μm, respectively. With variable PRF from 0.1 to 0.5kHz at V(in)=54 V(pp), k is increased from 0.20 to 0.42nN/μm. It is shown that a higher PRF leads to a more compliant trap formation (or a stronger F(trapping)) for a given displacement x. Hence the results suggest that this acoustic trapping method has the potential as a noninvasive manipulation tool for individual moving targets in microfluidics by adjusting the transducer's excitation parameters.Entities:
Mesh:
Year: 2012 PMID: 22824623 PMCID: PMC3746770 DOI: 10.1016/j.ultras.2012.06.008
Source DB: PubMed Journal: Ultrasonics ISSN: 0041-624X Impact factor: 2.890