Literature DB >> 22824249

Thickness of buccal bone in the mandible and its clinical significance in mono-cortical screws placement. A CBCT analysis.

B A Al-Jandan1, A A Al-Sulaiman, H F Marei, F A Syed, M Almana.   

Abstract

The aim of this study was to determine the safest length of monocortical screws that can be inserted for the treatment of mandibular fractures following Champy's technique. Fifty cone-beam computed tomography (CBCT) scans of hemi-mandibles were studied. Linear measurements were taken from the buccal cortical plate to the tooth apex, from the canine to the second premolar, and from the buccal cortical plate to the tooth apex and the inferior alveolar canal in the molar area. The minimum values of the horizontal distances both at the level of the apex and the inferior alveolar canal at the second molar were found to be 4 mm, which is greater than those of the first molar. At the canine, first premolar and second premolars, the minimum values of the horizontal distances at the level of the apex was found to be 2 mm, 2.33 mm and 2 mm, respectively. Stabilizing miniplates using 4 mm screws both at the level of the apex and the inferior alveolar canal is safe in the second molar area, anterior to this, there is a risk of injury to tooth root and inferior alveolar nerve.
Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22824249     DOI: 10.1016/j.ijom.2012.06.009

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  6 in total

Review 1.  Effective anaesthesia of the acutely inflamed pulp: part 2. Clinical strategies.

Authors:  S S Virdee; S Bhakta; D Seymour
Journal:  Br Dent J       Date:  2015-11-13       Impact factor: 1.626

2.  Standard 3D Titanium Miniplate Versus Locking 3D Miniplate in Fracture of Mandible: A Prospective Comparative Study.

Authors:  Arjun Singh; K V Arunkumar
Journal:  J Maxillofac Oral Surg       Date:  2015-07-29

3.  Role of fixation in posttraumatic nerve injury recovery in displaced mandibular angle fracture.

Authors:  R K Singh; U S Pal; Pranshu Singh; Geeta Singh
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

4.  Comparison of the Bone Harvesting Capacity of an Intraoral Bone Harvesting Device and Three Different Implant Drills.

Authors:  Hyun-Chang Lim; Kyung-In Ha; Ji-Youn Hong; Ji-Young Han; Seung-Il Shin; Seung-Yun Shin; Yeek Herr; Jong-Hyuk Chung
Journal:  Biomed Res Int       Date:  2017-12-14       Impact factor: 3.411

5.  Inferior alveolar nerve canal position in relation to mandibular molars: A cone-beam computed tomography study.

Authors:  K C Vidya; Jugajyoti Pathi; Sanjeeb Rout; Alok Sethi; N C Sangamesh
Journal:  Natl J Maxillofac Surg       Date:  2019-11-12

Review 6.  Buccal Bone Thickness in Anterior and Posterior Teeth-A Systematic Review.

Authors:  Diana Heimes; Eik Schiegnitz; Robert Kuchen; Peer W Kämmerer; Bilal Al-Nawas
Journal:  Healthcare (Basel)       Date:  2021-11-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.