Literature DB >> 22823748

Pulsatile pump decreases risk of delayed graft function in kidneys donated after cardiac death.

S A Lodhi1, K E Lamb, I Uddin, H U Meier-Kriesche.   

Abstract

Organ storage techniques have been under scrutiny to determine the best preservation method, particularly in donation after cardiac death (DCD) kidneys. Conflicting literature on the benefit of pulsatile perfusion (PP) over cold storage (CS) warrants further investigation. We analyzed the risk of developing delayed graft function (DGF) in recipients of DCD and donation after brain death (DBD) kidneys undergoing PP or CS. We stratified on basis of cold ischemic time (CIT) to determine the interaction of preservation techniques, CIT and DCD kidneys on developing DGF. Of 54 136 recipients, 4923 received DCD kidneys of which 3330 (67%) underwent PP. Of 49 213 DBD recipients, 7531 (15%) underwent PP. DCD had a higher risk of DGF versus DBD (adjusted odds ratio, AOR 3.2; 3.0-3.5). PP kidneys had less DGF (AOR 0.59; 0.56-0.63) compared to CS. Interaction models of method by donor type referenced to PP/DBD revealed CS/DBD kidneys had higher DGF (AOR 1.8; 1.7-1.9), whereas CS/DCD kidneys had the highest risk of DGF (AOR 5.01; 4.43-5.67). Even though suggestive for a benefit of PP on DGF, this retrospective analysis cannot address whether this is an intrinsic effect of PP or is associated with the logistics of PP such as discard of DCD kidneys based on pump parameters. © Copyright 2012 The American Society of Transplantation and the American Society of Transplant Surgeons.

Entities:  

Mesh:

Year:  2012        PMID: 22823748     DOI: 10.1111/j.1600-6143.2012.04179.x

Source DB:  PubMed          Journal:  Am J Transplant        ISSN: 1600-6135            Impact factor:   8.086


  10 in total

1.  Center-level variation in the development of delayed graft function after deceased donor kidney transplantation.

Authors:  Babak J Orandi; Nathan T James; Erin C Hall; Kyle J Van Arendonk; Jacqueline M Garonzik-Wang; Natasha Gupta; Robert A Montgomery; Niraj M Desai; Dorry L Segev
Journal:  Transplantation       Date:  2015-05       Impact factor: 4.939

2.  Preimplant histologic acute tubular necrosis and allograft outcomes.

Authors:  Isaac E Hall; Peter P Reese; Francis L Weng; Bernd Schröppel; Mona D Doshi; Rick D Hasz; William Reitsma; Michael J Goldstein; Kwangik Hong; Chirag R Parikh
Journal:  Clin J Am Soc Nephrol       Date:  2014-02-20       Impact factor: 8.237

3.  Machine perfusion and long-term kidney transplant recipient outcomes across allograft risk strata.

Authors:  Shaifali Sandal; Xun Luo; Allan B Massie; Steven Paraskevas; Marcelo Cantarovich; Dorry L Segev
Journal:  Nephrol Dial Transplant       Date:  2018-07-01       Impact factor: 5.992

4.  Metabolomic perfusate analysis during kidney machine perfusion: the pig provides an appropriate model for human studies.

Authors:  Jay Nath; Alison Guy; Thomas B Smith; Mark Cobbold; Nicholas G Inston; James Hodson; Daniel A Tennant; Christian Ludwig; Andrew R Ready
Journal:  PLoS One       Date:  2014-12-12       Impact factor: 3.240

Review 5.  Maximizing kidneys for transplantation using machine perfusion: from the past to the future: A comprehensive systematic review and meta-analysis.

Authors:  Ahmer M Hameed; Henry C Pleass; Germaine Wong; Wayne J Hawthorne
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

6.  Outcomes for primary kidney transplantation from donation after Citizens' death in China: a single center experience of 367 cases.

Authors:  Wujun Xue; Puxun Tian; Heli Xiang; Xiaoming Ding; Xiaoming Pan; Hang Yan; Jun Hou; Xinshun Feng; Linjuan Liu; Chenguang Ding; Xiaohui Tian; Yang Li; Jin Zheng
Journal:  BMC Health Serv Res       Date:  2017-04-04       Impact factor: 2.655

7.  Beneficial Effect of Moderately Increasing Hypothermic Machine Perfusion Pressure on Donor after Cardiac Death Renal Transplantation.

Authors:  Chen-Guang Ding; Pu-Xun Tian; Xiao-Ming Ding; He-Li Xiang; Yang Li; Xiao-Hui Tian; Feng Han; Qian-Hui Tai; Qian-Long Liu; Jin Zheng; Wu-Jun Xue
Journal:  Chin Med J (Engl)       Date:  2018-11-20       Impact factor: 2.628

8.  Predictive Score Model for Delayed Graft Function Based on Hypothermic Machine Perfusion Variables in Kidney Transplantation.

Authors:  Chen-Guang Ding; Yang Li; Xiao-Hui Tian; Xiao-Jun Hu; Pu-Xu Tian; Xiao-Ming Ding; He-Li Xiang; Jin Zheng; Wu-Jun Xue
Journal:  Chin Med J (Engl)       Date:  2018-11-20       Impact factor: 2.628

Review 9.  Does Rabbit Antithymocyte Globulin (Thymoglobuline®) Have a Role in Avoiding Delayed Graft Function in the Modern Era of Kidney Transplantation?

Authors:  Lluís Guirado
Journal:  J Transplant       Date:  2018-07-12

10.  Ex-vivo perfusion machines in kidney transplantation. The significance of the resistivity index.

Authors:  Florin Ioan Elec; Ciprian Lucan; Liviu Ghervan; Valentin Munteanu; Silviu Moga; Mihai Suciu; Dan Enache; Alina Elec; Adriana Munteanu; Adrian Barbos; Gheorghita Iacob; Mihai Lucan
Journal:  Clujul Med       Date:  2014-01-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.