Literature DB >> 22820326

Effects of disinfection on Legionella spp., eukarya, and biofilms in a hot water system.

Maha Farhat1, Marina Moletta-Denat, Jacques Frère, Séverine Onillon, Marie-Cécile Trouilhé, Enric Robine.   

Abstract

Legionella species are frequently detected in hot water systems, attached to the surface as a biofilm. In this work, the dynamics of Legionella spp. and diverse bacteria and eukarya associated together in the biofilm, coming from a pilot scale 1 system simulating a real hot water system, were investigated throughout 6 months after two successive heat shock treatments followed by three successive chemical treatments. Community structure was assessed by a fingerprint technique, single-strand conformation polymorphism (SSCP). In addition, the diversity and dynamics of Legionella and eukarya were investigated by small-subunit (SSU) ribosomal cloning and sequencing. Our results showed that pathogenic Legionella species remained after the heat shock and chemical treatments (Legionella pneumophila and Legionella anisa, respectively). The biofilm was not removed, and the bacterial community structure was transitorily affected by the treatments. Moreover, several amoebae had been detected in the biofilm before treatments (Thecamoebae sp., Vannella sp., and Hartmanella vermiformis) and after the first heat shock treatment, but only H. vermiformis remained. However, another protozoan affiliated with Alveolata, which is known as a host cell for Legionella, dominated the eukaryal species after the second heat shock and chemical treatment tests. Therefore, effective Legionella disinfection may be dependent on the elimination of these important microbial components. We suggest that eradicating Legionella in hot water networks requires better study of bacterial and eukaryal species associated with Legionella in biofilms.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22820326      PMCID: PMC3457500          DOI: 10.1128/AEM.00831-12

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  65 in total

1.  Enumeration of Legionella pneumophila in cooling tower water systems.

Authors:  Irfan Türetgen; Esra Ilhan Sungur; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2005-01       Impact factor: 2.513

2.  Resistance of Legionella to disinfection in hot water distribution systems.

Authors:  S Saby; A Vidal; H Suty
Journal:  Water Sci Technol       Date:  2005       Impact factor: 1.915

3.  Passage through Tetrahymena tropicalis triggers a rapid morphological differentiation in Legionella pneumophila.

Authors:  Gary Faulkner; Sharon G Berk; Elizabeth Garduño; Marco A Ortiz-Jiménez; Rafael A Garduño
Journal:  J Bacteriol       Date:  2008-09-19       Impact factor: 3.490

4.  Characterization of a Legionella anisa strain isolated from a patient with pneumonia.

Authors:  W L Thacker; R F Benson; L Hawes; W R Mayberry; D J Brenner
Journal:  J Clin Microbiol       Date:  1990-01       Impact factor: 5.948

5.  Legionella incidence and density in potable drinking water supplies.

Authors:  D L Tison; R J Seidler
Journal:  Appl Environ Microbiol       Date:  1983-01       Impact factor: 4.792

Review 6.  Legionella-like amebal pathogens--phylogenetic status and possible role in respiratory disease.

Authors:  A Adeleke; J Pruckler; R Benson; T Rowbotham; M Halablab; B Fields
Journal:  Emerg Infect Dis       Date:  1996 Jul-Sep       Impact factor: 6.883

7.  Survival of Legionella pneumophila in the cold-water ciliate Tetrahymena vorax.

Authors:  H E Smith-Somerville; V B Huryn; C Walker; A L Winters
Journal:  Appl Environ Microbiol       Date:  1991-09       Impact factor: 4.792

8.  Amoebae in domestic water systems: resistance to disinfection treatments and implication in Legionella persistence.

Authors:  V Thomas; T Bouchez; V Nicolas; S Robert; J F Loret; Y Lévi
Journal:  J Appl Microbiol       Date:  2004       Impact factor: 3.772

Review 9.  Legionella pneumophila: population genetics, phylogeny and genomics.

Authors:  L Gomez-Valero; C Rusniok; C Buchrieser
Journal:  Infect Genet Evol       Date:  2009-05-18       Impact factor: 3.342

10.  Multiplication of Legionella spp. in tap water containing Hartmannella vermiformis.

Authors:  R M Wadowsky; T M Wilson; N J Kapp; A J West; J M Kuchta; S J States; J N Dowling; R B Yee
Journal:  Appl Environ Microbiol       Date:  1991-07       Impact factor: 4.792

View more
  19 in total

Review 1.  Current and emerging Legionella diagnostics for laboratory and outbreak investigations.

Authors:  Jeffrey W Mercante; Jonas M Winchell
Journal:  Clin Microbiol Rev       Date:  2015-01       Impact factor: 26.132

2.  Combining Traditional and Molecular Techniques Supports the Discovery of a Novel Legionella Species During Environmental Surveillance in a Healthcare Facility.

Authors:  Luna Girolamini; Maria Rosaria Pascale; Marta Mazzotta; Simona Spiteri; Federica Marino; Silvano Salaris; Antonella Grottola; Massimiliano Orsini; Sandra Cristino
Journal:  Front Microbiol       Date:  2022-06-13       Impact factor: 6.064

3.  Viable but not culturable forms of Legionella pneumophila generated after heat shock treatment are infectious for macrophage-like and alveolar epithelial cells after resuscitation on Acanthamoeba polyphaga.

Authors:  Thibaut Epalle; Françoise Girardot; Séverine Allegra; Cécile Maurice-Blanc; Olivier Garraud; Serge Riffard
Journal:  Microb Ecol       Date:  2014-07-30       Impact factor: 4.552

4.  Impact of environmental factors on legionella populations in drinking water.

Authors:  David Otto Schwake; Absar Alum; Morteza Abbaszadegan
Journal:  Pathogens       Date:  2015-05-19

5.  Effect of heat shock on hot water plumbing microbiota and Legionella pneumophila control.

Authors:  Pan Ji; William J Rhoads; Marc A Edwards; Amy Pruden
Journal:  Microbiome       Date:  2018-02-09       Impact factor: 14.650

Review 6.  Factors Mediating Environmental Biofilm Formation by Legionella pneumophila.

Authors:  Arwa Abu Khweek; Amal O Amer
Journal:  Front Cell Infect Microbiol       Date:  2018-02-27       Impact factor: 5.293

7.  Impact of water heater temperature setting and water use frequency on the building plumbing microbiome.

Authors:  Pan Ji; William J Rhoads; Marc A Edwards; Amy Pruden
Journal:  ISME J       Date:  2017-03-10       Impact factor: 10.302

8.  Legionella confirmation in cooling tower water. Comparison of culture, real-time PCR and next generation sequencing.

Authors:  Maha Farhat; Raja A Shaheed; Haider H Al-Ali; Abdullah S Al-Ghamdi; Ghadeer M Al-Hamaqi; Hawraa S Maan; Zainab A Al-Mahfoodh; Hussain Z Al-Seba
Journal:  Saudi Med J       Date:  2018-02       Impact factor: 1.484

9.  The LetA/S two-component system regulates transcriptomic changes that are essential for the culturability of Legionella pneumophila in water.

Authors:  Nilmini Mendis; Peter McBride; Joseph Saoud; Thangadurai Mani; Sebastien P Faucher
Journal:  Sci Rep       Date:  2018-04-30       Impact factor: 4.379

10.  Advances in Legionella Control by a New Formulation of Hydrogen Peroxide and Silver Salts in a Hospital Hot Water Network.

Authors:  Luna Girolamini; Ada Dormi; Tiziana Pellati; Paolo Somaroli; Davide Montanari; Andrea Costa; Francesca Savelli; Andrea Martelli; Antonella Grottola; Giulia Fregni Serpini; Sandra Cristino
Journal:  Pathogens       Date:  2019-10-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.