Literature DB >> 22819583

Nonlocal maximum likelihood estimation method for denoising multiple-coil magnetic resonance images.

Jeny Rajan1, Jelle Veraart, Johan Van Audekerke, Marleen Verhoye, Jan Sijbers.   

Abstract

Effective denoising is vital for proper analysis and accurate quantitative measurements from magnetic resonance (MR) images. Even though many methods were proposed to denoise MR images, only few deal with the estimation of true signal from MR images acquired with phased-array coils. If the magnitude data from phased array coils are reconstructed as the root sum of squares, in the absence of noise correlations and subsampling, the data is assumed to follow a non central-χ distribution. However, when the k-space is subsampled to increase the acquisition speed (as in GRAPPA like methods), noise becomes spatially varying. In this note, we propose a method to denoise multiple-coil acquired MR images. Both the non central-χ distribution and the spatially varying nature of the noise is taken into account in the proposed method. Experiments were conducted on both simulated and real data sets to validate and to demonstrate the effectiveness of the proposed method.
Copyright © 2012 Elsevier Inc. All rights reserved.

Mesh:

Year:  2012        PMID: 22819583     DOI: 10.1016/j.mri.2012.04.021

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  9 in total

1.  A majorize-minimize framework for Rician and non-central chi MR images.

Authors:  Divya Varadarajan; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2015-04-28       Impact factor: 10.048

2.  Retrospective correction of bias in diffusion tensor imaging arising from coil combination mode.

Authors:  Ken Sakaie; Mark Lowe
Journal:  Magn Reson Imaging       Date:  2016-12-05       Impact factor: 2.546

3.  Noise Estimation and Reduction in Magnetic Resonance Imaging Using a New Multispectral Nonlocal Maximum-likelihood Filter.

Authors:  Mustapha Bouhrara; Jean-Marie Bonny; Beth G Ashinsky; Michael C Maring; Richard G Spencer
Journal:  IEEE Trans Med Imaging       Date:  2016-08-18       Impact factor: 10.048

4.  Free-breathing liver fat and R 2 quantification using motion-corrected averaging based on a nonlocal means algorithm.

Authors:  Huiwen Luo; Ante Zhu; Curtis N Wiens; Jitka Starekova; Ann Shimakawa; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

5.  Denoising of diffusion MRI using random matrix theory.

Authors:  Jelle Veraart; Dmitry S Novikov; Daan Christiaens; Benjamin Ades-Aron; Jan Sijbers; Els Fieremans
Journal:  Neuroimage       Date:  2016-08-11       Impact factor: 6.556

6.  A simple noise correction scheme for diffusional kurtosis imaging.

Authors:  G Russell Glenn; Ali Tabesh; Jens H Jensen
Journal:  Magn Reson Imaging       Date:  2014-08-28       Impact factor: 2.546

Review 7.  Quick guide on radiology image pre-processing for deep learning applications in prostate cancer research.

Authors:  Samira Masoudi; Stephanie A Harmon; Sherif Mehralivand; Stephanie M Walker; Harish Raviprakash; Ulas Bagci; Peter L Choyke; Baris Turkbey
Journal:  J Med Imaging (Bellingham)       Date:  2021-01-06

8.  A MRI Denoising Method Based on 3D Nonlocal Means and Multidimensional PCA.

Authors:  Liu Chang; Gao ChaoBang; Yu Xi
Journal:  Comput Math Methods Med       Date:  2015-10-12       Impact factor: 2.238

9.  An enhanced adaptive non-local means algorithm for Rician noise reduction in magnetic resonance brain images.

Authors:  Kaixin Chen; Xiao Lin; Xing Hu; Jiayao Wang; Han Zhong; Linhua Jiang
Journal:  BMC Med Imaging       Date:  2020-01-06       Impact factor: 1.930

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.