Literature DB >> 22817941

Cadmium determination in natural water samples with an automatic multisyringe flow injection system coupled to a flow-through screen printed electrode.

C Henríquez1, L M Laglera, M J Alpizar, J Calvo, F Arduini, V Cerdà.   

Abstract

Heavy metals, as cadmium, attract a rising attention in environmental studies due to their increasing release by human activities and acute toxicity. In situ analytical methods are needed to minimize current uncertainties caused by the transport and conservation of samples. Here, we present the completely automatic determination of Cd in natural waters using a newly developed screen printed electrode sensor (SPE), inserted in a homemade purpose-built flow cell coupled to a Multi-Syringe Flow Injection Analysis system (MSFIA). The working electrode of SPEs was constituted by a carbon film modified with Nafion. Cd was plated on an in situ bismuth film and determined using Square Wave Anodic Stripping Voltammetry. Different chemical conditions of deposition and stripping were studied. A sample/acetic buffer mixture was found to be a well suited medium to form the Bi film and perform the analysis. Cd was quantified via calibration by on line standard additions. The limit of detection was found to be 0.79μgL(-1), well below the limit stipulated by the European directive (5μgL(-1)). Good sample throughput (14h(-1)) and low consumption of reagent and sample (1.3mL) were also obtained in line with previous works in Cd flow analysis.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22817941     DOI: 10.1016/j.talanta.2012.01.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Screen-Printed Electrodes Modified with "Green" Metals for Electrochemical Stripping Analysis of Toxic Elements.

Authors:  Anastasios Economou
Journal:  Sensors (Basel)       Date:  2018-03-29       Impact factor: 3.576

2.  Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell.

Authors:  Guo Zhao; Thien-Toan Tran; Sidharth Modha; Mohammed Sedki; Nosang V Myung; David Jassby; Ashok Mulchandani
Journal:  Front Chem       Date:  2022-02-17       Impact factor: 5.221

Review 3.  Disposable screen printed electrochemical sensors: tools for environmental monitoring.

Authors:  Akhtar Hayat; Jean Louis Marty
Journal:  Sensors (Basel)       Date:  2014-06-13       Impact factor: 3.576

Review 4.  Electrochemical Biosensors: A Solution to Pollution Detection with Reference to Environmental Contaminants.

Authors:  Gustavo Hernandez-Vargas; Juan Eduardo Sosa-Hernández; Sara Saldarriaga-Hernandez; Angel M Villalba-Rodríguez; Roberto Parra-Saldivar; Hafiz M N Iqbal
Journal:  Biosensors (Basel)       Date:  2018-03-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.