Literature DB >> 22817831

Descemet's stripping automated endothelial keratoplasty: the tenuous relationship between donor thickness and postoperative vision.

Mark A Terry1, Michael D Straiko, Jeffrey M Goshe, Jennifer Y Li, David Davis-Boozer.   

Abstract

PURPOSE: To determine whether preoperative donor thickness has a relationship with postoperative visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK).
DESIGN: Retrospective correlation and comparative analysis of an interventional case series. PARTICIPANTS: A total of 418 eyes of 292 patients undergoing DSAEK surgery for Fuchs' endothelial dystrophy without visual loss from comorbidities.
METHODS: Descemet's stripping automated endothelial keratoplasty was performed in 548 eyes with Fuchs' dystrophy, and preoperative graft thickness (GT) was recorded. After exclusion of patients with confounding variables that would affect postoperative visual acuity, postoperative best spectacle-corrected visual acuity (BSCVA) was measured at 6 months in 418 eyes. Pearson's correlation analysis was performed between preoperative GT and BSCVA. Cases were split into deciles on the basis of GT and BSCVA and then compared with 1-way analysis of variance (ANOVA) and chi-square test. MAIN OUTCOME MEASURES: Best spectacle-corrected visual acuity at 6 months postoperatively.
RESULTS: Mean GT of the series was 162.9±29.0 μm (range, 80-265 μm), and mean Snellen BSCVA was 20/28 with a range of 20/16 to 20/70. There was a weak correlation between GT and BSCVA that was significant (R = 0.236, P<0.001) but only accounted for 5% of the visual outcome (R(2) = 0.056). Visual outcome was best within the thinnest decile group of 45 donors (GT range, 80-124), with a mean Snellen BSCVA of 20/25 (range, 20/20-20/50), and worst within the thickest decile group of 41 donors (GT range, 200-265), with a mean Snellen BSCVA of 20/33 (range, 20/20-20/70). Post hoc comparison of BSCVA between the thickest and thinnest groups was significant (P = 0.006).
CONCLUSIONS: Preoperative GT may have a small effect on visual outcome in the extremes of thickness, but not in the common range of 100 to 200 μm. Donor thickness has a tenuous relationship with visual outcome, accounting for only 5% of the variance in vision between patients, and should play a minimal role in surgical planning.
Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22817831     DOI: 10.1016/j.ophtha.2012.05.021

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  21 in total

1.  Donor, Recipient, and Operative Factors Associated with Graft Success in the Cornea Preservation Time Study.

Authors:  Mark A Terry; Anthony J Aldave; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Christopher Croasdale; Yassine J Daoud; Steven P Dunn; Caroline K Hoover; Marian S Macsai; Thomas F Mauger; Sudeep Pramanik; George O D Rosenwasser; Jennifer Rose-Nussbaumer; R Doyle Stulting; Alan Sugar; Elmer Y Tu; David D Verdier; Sonia H Yoo; Jonathan H Lass
Journal:  Ophthalmology       Date:  2018-08-09       Impact factor: 12.079

2.  Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty.

Authors:  Chenxing Zhang; Matthew Bald; Maolong Tang; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2015-03-04       Impact factor: 3.351

3.  "OSMO-UT-DSAEK" using THIN-C medium.

Authors:  F Bucher; S Roters; A Mellein; D Hos; L M Heindl; C Cursiefen; M Hermann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-02       Impact factor: 3.117

4.  Evaluation of factors affecting visual acuity after Descemet stripping automated endothelial keratoplasty.

Authors:  Shiro Amano; Akira Setogawa; Kenji Inoue
Journal:  Jpn J Ophthalmol       Date:  2016-12-10       Impact factor: 2.447

5.  Corneal nerve alterations in different stages of Fuchs' endothelial corneal dystrophy: an in vivo confocal microscopy study.

Authors:  Franziska Bucher; Werner Adler; Helmar C Lehmann; Deniz Hos; Philipp Steven; Claus Cursiefen; Ludwig M Heindl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-30       Impact factor: 3.117

6.  Post-DSAEK optical changes: a comprehensive prospective analysis on the role of ocular wavefront aberrations, haze, and corneal thickness.

Authors:  Holly B Hindman; Krystel R Huxlin; Seth M Pantanelli; Christine L Callan; Ramkumar Sabesan; Steven S T Ching; Brooke E Miller; Tim Martin; Geunyoung Yoon
Journal:  Cornea       Date:  2013-12       Impact factor: 2.651

7.  [Influence of donor lamella thickness on visual acuity after Descemet's stripping automated endothelial keratoplasty (DSAEK)].

Authors:  A-K B Maier; E Gundlach; M K J Klamann; J Gonnermann; E Bertelmann; A M Joussen; N Torun; P W Rieck
Journal:  Ophthalmologe       Date:  2014-02       Impact factor: 1.059

8.  Factors Associated With Graft Rejection in the Cornea Preservation Time Study.

Authors:  R Doyle Stulting; Jonathan H Lass; Mark A Terry; Beth Ann Benetz; Nathan J Cohen; Allison R Ayala; Maureen G Maguire; Christopher Croasdale; Yassine J Daoud; Steven P Dunn; Kenneth M Goins; Pankaj C Gupta; Marian S Macsai; Shahzad I Mian; Sudeep Pramanik; Jennifer Rose-Nussbaumer; Jonathan C Song; Walter J Stark; Alan Sugar; David D Verdier; Loretta B Szczotka-Flynn
Journal:  Am J Ophthalmol       Date:  2018-10-09       Impact factor: 5.258

9.  Prelamellar Dissection Donor Corneal Thickness Is Associated With Descemet Stripping Automated Endothelial Keratoplasty Operative Complications in the Cornea Preservation Time Study.

Authors:  Kevin W Ross; Christopher G Stoeger; George O D Rosenwasser; Robert C OʼBrien; Loretta B Szczotka-Flynn; Allison R Ayala; Maureen G Maguire; Beth Ann Benetz; Patricia Dahl; Donna C Drury; Steven P Dunn; Sameera M Farazdaghi; Caroline K Hoover; Marian S Macsai; Shahzad I Mian; Michael L Nordlund; Jeffrey G Penta; Mark C Soper; Mark A Terry; David D Verdier; Doyce V Williams; Jonathan H Lass
Journal:  Cornea       Date:  2019-09       Impact factor: 3.152

10.  Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy.

Authors:  Remzi Karadag; Kristin M Hammersmith; Parveen K Nagra; Christopher J Rapuano
Journal:  J Ophthalmic Vis Res       Date:  2021-04-29
View more