Bioimpedance-based measurement method for simultaneous acquisition of respiratory and cardiac gating signals.

T Koivumäki1, M Vauhkonen, J T Kuikka, M A Hakulinen.   

Abstract

Respiratory and cardiac motion artefacts impair the quality and reliability of medical imaging, particularly in nuclear medicine. At worst, the interpretation of distorted images may lead to inadequate or unnecessary treatment. Image artefacts can be minimized by gating the image acquisition according to respiratory phase and cardiac contractions. However, currently there are no clinically established dual-gating methods in nuclear medicine imaging. The aim of this study is to validate a previously determined optimized bioimpedance measurement configuration against traditional respiratory and cardiac measurement systems in 12 volunteers. High agreement and excellent correlations (r = 0.944-0.999) were found between respiratory peak-to-peak amplitudes as well as temporal respiratory and cardiac intervals. Above all, good quality respiratory and cardiac gating signals were obtained from all test subjects with a fairly regular sinus rhythm. Importantly, both signals were acquired simultaneously with a single device. Due to the simplicity of this inexpensive method, the technique has high potential to be adopted for dual-gating in clinical practice in the future.

Mesh:

Year:  2012        PMID: 22813948     DOI: 10.1088/0967-3334/33/8/1323

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  5 in total

1.  Derivation of a respiration trigger signal in small animal list-mode PET based on respiration-induced variations of the ECG signal.

Authors:  Andrei Todica; Sebastian Lehner; Hao Wang; Mathias J Zacherl; Katharina Nekolla; Erik Mille; Guoming Xiong; Peter Bartenstein; Christian la Fougère; Marcus Hacker; Guido Böning
Journal:  J Nucl Cardiol       Date:  2015-06-12       Impact factor: 5.952

2.  Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging.

Authors:  Mojtaba Jafari Tadi; Tero Koivisto; Mikko Pänkäälä; Ari Paasio
Journal:  Int J Biomed Imaging       Date:  2014-07-10

3.  Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

Authors:  Kirpal Kohli; Jeff Liu; Devin Schellenberg; Anand Karvat; Ash Parameswaran; Parvind Grewal; Steven Thomas
Journal:  Biomed Eng Online       Date:  2014-10-14       Impact factor: 2.819

4.  Estimation of optimal number of gates in dual gated 18F-FDG cardiac PET.

Authors:  R Klén; J Teuho; T Noponen; K Thielemans; E Hoppela; E Lehtonen; H T Sipila; M Teräs; J Knuuti
Journal:  Sci Rep       Date:  2020-11-09       Impact factor: 4.379

5.  Chest Movement and Respiratory Volume both Contribute to Thoracic Bioimpedance during Loaded Breathing.

Authors:  Dolores Blanco-Almazán; Willemijn Groenendaal; Francky Catthoor; Raimon Jané
Journal:  Sci Rep       Date:  2019-12-27       Impact factor: 4.379