Literature DB >> 22813783

Next-generation low-cost motion capture systems can provide comparable spatial accuracy to high-end systems.

Dominic Thewlis1, Chris Bishop, Nathan Daniell, Gunther Paul.   

Abstract

The objective quantification of three-dimensional kinematics during different functional and occupational tasks is now more in demand than ever. The introduction of new generation of low-cost passive motion capture systems from a number of manufacturers has made this technology accessible for teaching, clinical practice and in small/medium industry. Despite the attractive nature of these systems, their accuracy remains unproved in independent tests. We assessed static linear accuracy, dynamic linear accuracy and compared gait kinematics from a Vicon MX20 system to a Natural Point OptiTrack system. In all experiments data were sampled simultaneously. We identified both systems perform excellently in linear accuracy tests with absolute errors not exceeding 1%. In gait data there was again strong agreement between the two systems in sagittal and coronal plane kinematics. Transverse plane kinematics differed by up to 3° at the knee and hip, which we attributed to the impact of soft tissue artifact accelerations on the data. We suggest that low-cost systems are comparably accurate to their high-end competitors and offer a platform with accuracy acceptable in research for laboratories with a limited budget.

Mesh:

Year:  2012        PMID: 22813783     DOI: 10.1123/jab.29.1.112

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  12 in total

1.  Octopus: A Design Methodology for Motion Capture Wearables.

Authors:  Javier Marin; Teresa Blanco; Jose J Marin
Journal:  Sensors (Basel)       Date:  2017-08-15       Impact factor: 3.576

2.  A Perspective on Wearable Sensor Measurements and Data Science for Parkinson's Disease.

Authors:  Ricardo Matias; Vitor Paixão; Raquel Bouça; Joaquim J Ferreira
Journal:  Front Neurol       Date:  2017-12-12       Impact factor: 4.003

3.  Validity of a New 3-D Motion Analysis Tool for the Assessment of Knee, Hip and Spine Joint Angles during the Single Leg Squat.

Authors:  Igor Tak; Willem-Paul Wiertz; Maarten Barendrecht; Rob Langhout
Journal:  Sensors (Basel)       Date:  2020-08-13       Impact factor: 3.576

4.  Exploring wearable sensors as an alternative to marker-based motion capture in the pitching delivery.

Authors:  Kyle J Boddy; Joseph A Marsh; Alex Caravan; Kyle E Lindley; John O Scheffey; Michael E O'Connell
Journal:  PeerJ       Date:  2019-01-24       Impact factor: 2.984

5.  Affordable gait analysis using augmented reality markers.

Authors:  Gergely Nagymáté; Rita M Kiss
Journal:  PLoS One       Date:  2019-02-14       Impact factor: 3.240

6.  Validity of inertial sensor based 3D joint kinematics of static and dynamic sport and physiotherapy specific movements.

Authors:  Wolfgang Teufl; Markus Miezal; Bertram Taetz; Michael Fröhlich; Gabriele Bleser
Journal:  PLoS One       Date:  2019-02-28       Impact factor: 3.240

7.  Validity and reliability of the Kinovea program in obtaining angles and distances using coordinates in 4 perspectives.

Authors:  Albert Puig-Diví; Carles Escalona-Marfil; Josep Maria Padullés-Riu; Albert Busquets; Xavier Padullés-Chando; Daniel Marcos-Ruiz
Journal:  PLoS One       Date:  2019-06-05       Impact factor: 3.240

8.  Automatic characterization of stride parameters in canines with a single wearable inertial sensor.

Authors:  Gregory J Jenkins; Chady H Hakim; N Nora Yang; Gang Yao; Dongsheng Duan
Journal:  PLoS One       Date:  2018-06-14       Impact factor: 3.240

9.  Effects of a six-week weighted-implement throwing program on baseball pitching velocity, kinematics, arm stress, and arm range of motion.

Authors:  Joseph A Marsh; Matthew I Wagshol; Kyle J Boddy; Michael E O'Connell; Sam J Briend; Kyle E Lindley; Alex Caravan
Journal:  PeerJ       Date:  2018-11-23       Impact factor: 2.984

10.  Integrating a gait analysis test in hospital rehabilitation: A service design approach.

Authors:  Javier Marín; Teresa Blanco; José J Marín; Alejandro Moreno; Elena Martitegui; Juan C Aragüés
Journal:  PLoS One       Date:  2019-10-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.