Literature DB >> 22813723

Reliability and accuracy in three-dimensional gait analysis: a comparison of two lower body protocols.

Felix Stief1, Harald Böhm, Katja Michel, Ansgar Schwirtz, Leonhard Döderlein.   

Abstract

The standard Plug-in-Gait (PiG) protocol used in three-dimensional gait analysis is prone to errors arising from inconsistent anatomical landmark identification and knee axis malalignment. The purpose of this study was to estimate the reliability and accuracy of a custom made lower body protocol (MA) compared with the PiG protocol. Twenty-five subjects volunteered to evaluate the intertrial reliability. In addition, intersession reliability was examined in 10 participants. An indirect indicator of accuracy according to the knee varus/valgus and flexion/extension range of motion (ROM) was used. Regarding frontal plane knee angles and moments as well as transverse plane motions in the knee and hip joint, the intersession errors were lower for the MA compared with the standard approach. In reference to the knee joint angle cross-talk, the MA produced 4.7° more knee flexion/extension ROM and resulted in 6.5° less knee varus/valgus ROM in the frontal plane. Therefore, the MA tested in this study produced a more accurate and reliable knee joint axis compared with the PiG protocol. These results are especially important for measuring frontal and transverse plane gait parameters.

Entities:  

Mesh:

Year:  2012        PMID: 22813723     DOI: 10.1123/jab.29.1.105

Source DB:  PubMed          Journal:  J Appl Biomech        ISSN: 1065-8483            Impact factor:   1.833


  10 in total

1.  Recurrent patellar dislocations in adolescents result in decreased knee flexion during the entire gait cycle.

Authors:  Carlo Camathias; Elias Ammann; Rahel L Meier; Erich Rutz; Patrick Vavken; Kathrin Studer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-03-04       Impact factor: 4.342

Review 2.  Methodological factors affecting joint moments estimation in clinical gait analysis: a systematic review.

Authors:  Valentina Camomilla; Andrea Cereatti; Andrea Giovanni Cutti; Silvia Fantozzi; Rita Stagni; Giuseppe Vannozzi
Journal:  Biomed Eng Online       Date:  2017-08-18       Impact factor: 2.819

3.  Effects of ankle-foot braces on medial gastrocnemius morphometrics and gait in children with cerebral palsy.

Authors:  Matthias Hösl; Harald Böhm; Adamantios Arampatzis; Leonhard Döderlein
Journal:  J Child Orthop       Date:  2015-06-25       Impact factor: 1.548

4.  Accuracy of a custom physical activity and knee angle measurement sensor system for patients with neuromuscular disorders and gait abnormalities.

Authors:  Frank Feldhege; Anett Mau-Moeller; Tobias Lindner; Albert Hein; Andreas Markschies; Uwe Klaus Zettl; Rainer Bader
Journal:  Sensors (Basel)       Date:  2015-05-06       Impact factor: 3.576

5.  The effect of subject measurement error on joint kinematics in the conventional gait model: Insights from the open-source pyCGM tool using high performance computing methods.

Authors:  Mathew Schwartz; Philippe C Dixon
Journal:  PLoS One       Date:  2018-01-02       Impact factor: 3.240

6.  Estimation of Vertical Ground Reaction Forces and Sagittal Knee Kinematics During Running Using Three Inertial Sensors.

Authors:  Frank J Wouda; Matteo Giuberti; Giovanni Bellusci; Erik Maartens; Jasper Reenalda; Bert-Jan F van Beijnum; Peter H Veltink
Journal:  Front Physiol       Date:  2018-03-22       Impact factor: 4.566

7.  Are changes in radiological leg alignment and femoral parameters after total hip replacement responsible for joint loading during gait?

Authors:  Stefan van Drongelen; Hanna Kaldowski; Timur Tarhan; Ayman Assi; Andrea Meurer; Felix Stief
Journal:  BMC Musculoskelet Disord       Date:  2019-11-10       Impact factor: 2.362

8.  Identification of Patients with Similar Gait Compensating Strategies Due to Unilateral Hip Osteoarthritis and the Effect of Total Hip Replacement: A Secondary Analysis.

Authors:  Stefan van Drongelen; Bernd J Stetter; Harald Böhm; Felix Stief; Thorsten Stein; Andrea Meurer
Journal:  J Clin Med       Date:  2021-05-17       Impact factor: 4.241

9.  Characteristics of ataxic gait in familial dysautonomia patients.

Authors:  Sigal Portnoy; Channa Maayan; Jeanna Tsenter; Yonah Ofran; Vladimir Goldman; Nurit Hiller; Naama Karniel; Isabella Schwartz
Journal:  PLoS One       Date:  2018-04-26       Impact factor: 3.240

10.  Impact of Altered Gastrocnemius Morphometrics and Fascicle Behavior on Walking Patterns in Children With Spastic Cerebral Palsy.

Authors:  Matthias Hösl; Annika Kruse; Markus Tilp; Martin Svehlik; Harald Böhm; Antonia Zehentbauer; Adamantios Arampatzis
Journal:  Front Physiol       Date:  2020-10-07       Impact factor: 4.755

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.