Literature DB >> 22809539

How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram.

Axel Schäfer1, Jan Vagedes.   

Abstract

BACKGROUND: The usefulness of heart rate variability (HRV) as a clinical research and diagnostic tool has been verified in numerous studies. The gold standard technique comprises analyzing time series of RR intervals from an electrocardiographic signal. However, some authors have used pulse cycle intervals instead of RR intervals, as they can be determined from a pulse wave (e.g. a photoplethysmographic) signal. This option is often called pulse rate variability (PRV), and utilizing it could expand the serviceability of pulse oximeters or simplify ambulatory monitoring of HRV.
METHODS: We review studies investigating the accuracy of PRV as an estimate of HRV, regardless of the underlying technology (photoplethysmography, continuous blood pressure monitoring or Finapresi, impedance plethysmography). RESULTS/
CONCLUSIONS: Results speak in favor of sufficient accuracy when subjects are at rest, although many studies suggest that short-term variability is somewhat overestimated by PRV, which reflects coupling effects between respiration and the cardiovascular system. Physical activity and some mental stressors seem to impair the agreement of PRV and HRV, often to an inacceptable extent. Findings regarding the position of the sensor or the detection algorithm are not conclusive. Generally, quantitative conclusions are impeded by the fact that results of different studies are mostly incommensurable due to diverse experimental settings and/or methods of analysis.
Copyright © 2012. Published by Elsevier Ireland Ltd.

Mesh:

Year:  2012        PMID: 22809539     DOI: 10.1016/j.ijcard.2012.03.119

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  125 in total

1.  Influence of a skin status on the light interaction with dermis.

Authors:  Alexei A Kamshilin; Oleg V Mamontov; Vasily T Koval; Grigory A Zayats; Roman V Romashko
Journal:  Biomed Opt Express       Date:  2015-10-08       Impact factor: 3.732

2.  Effect of changes in sympathovagal balance on the accuracy of heart rate variability obtained from photoplethysmography.

Authors:  Xiang Chen; Yuan-Yuan Huang; Feng Yun; Tian-Jun Chen; Jin Li
Journal:  Exp Ther Med       Date:  2015-10-02       Impact factor: 2.447

3.  Physiological and behavioral responses reveal 9-month-old infants' sensitivity to pleasant touch.

Authors:  Merle T Fairhurst; Line Löken; Tobias Grossmann
Journal:  Psychol Sci       Date:  2014-03-28

4.  Chemosensory perception, symptoms and autonomic responses during chemical exposure in multiple chemical sensitivity.

Authors:  Linus Andersson; Anna-Sara Claeson; Thomas Meinertz Dantoft; Sine Skovbjerg; Nina Lind; Steven Nordin
Journal:  Int Arch Occup Environ Health       Date:  2015-04-28       Impact factor: 3.015

5.  Using the multi-parameter variability of photoplethysmographic signals to evaluate short-term cardiovascular regulation.

Authors:  Xiang Chen; Ning Liu; Yuanyuan Huang; Feng Yun; Jue Wang; Jin Li
Journal:  J Clin Monit Comput       Date:  2014-11-19       Impact factor: 2.502

6.  Comparison of short-term heart rate variability indexes evaluated through electrocardiographic and continuous blood pressure monitoring.

Authors:  Riccardo Pernice; Michal Javorka; Jana Krohova; Barbora Czippelova; Zuzana Turianikova; Alessandro Busacca; Luca Faes
Journal:  Med Biol Eng Comput       Date:  2019-02-07       Impact factor: 2.602

7.  Spectral-spatial fusion model for robust blood pulse waveform extraction in photoplethysmographic imaging.

Authors:  Robert Amelard; David A Clausi; Alexander Wong
Journal:  Biomed Opt Express       Date:  2016-11-01       Impact factor: 3.732

8.  Accurate measurement of the pulse wave delay with imaging photoplethysmography.

Authors:  Alexei A Kamshilin; Igor S Sidorov; Laura Babayan; Maxim A Volynsky; Rashid Giniatullin; Oleg V Mamontov
Journal:  Biomed Opt Express       Date:  2016-11-16       Impact factor: 3.732

9.  The Accuracy of Acquiring Heart Rate Variability from Portable Devices: A Systematic Review and Meta-Analysis.

Authors:  Ward C Dobbs; Michael V Fedewa; Hayley V MacDonald; Clifton J Holmes; Zackary S Cicone; Daniel J Plews; Michael R Esco
Journal:  Sports Med       Date:  2019-03       Impact factor: 11.136

10.  Association between heart rate variability and fluctuations in resting-state functional connectivity.

Authors:  Catie Chang; Coraline D Metzger; Gary H Glover; Jeff H Duyn; Hans-Jochen Heinze; Martin Walter
Journal:  Neuroimage       Date:  2012-12-12       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.