Literature DB >> 22804816

Comparison of plaque accumulation and soft-tissue blood flow with the use of full-arch implant-supported fixed prostheses with mucosal surfaces of different materials: a randomized clinical study.

Masato Kanao1, Tetsuji Nakamoto, Norihiro Kajiwara, Yusuke Kondo, Chihiro Masaki, Ryuji Hosokawa.   

Abstract

OBJECTIVE: The aims of this clinical study were to determine differences in plaque accumulation and to compare the effects of reinforced composite resin and titanium on peri-implant soft-tissue and residual-ridge inflammation.
MATERIAL AND METHODS: A total of 19 subjects were enrolled in this clinical trial; 10 jaws had implant-supported fixed prostheses with composite resin mucosal surfaces, 11 jaws had titanium prostheses fabricated by computer-aided design/computer-aided manufacture (CAD/CAM), and 6 jaws had acrylic resin prostheses. Plaque area indexes (PAIs) were calculated on the mucosal surfaces of prostheses, and blood flow in the mucosa was captured with two-dimensional laser speckle imaging to evaluate residual-ridge inflammation. Subjects were educated about oral hygiene and reevaluated after 3 months.
RESULTS: The PAI was significantly lower on titanium mucosal surfaces than on reinforced composite resin surfaces at the initial and second measurements (initial, P = 0.0052; second, P = 0.0044). Self-curing acrylic resin surfaces did not show any significant difference when compared with reinforced resin or titanium. Blood flow was significantly lower in mucosa contacting titanium surfaces than in mucosa contacting reinforced composite resin surfaces at the initial measurement (P = 0.0330). Although subjects were instructed about plaque control after the initial measurement, PAIs indicated that the difference between the two materials could not be overcome.
CONCLUSION: In terms of oral hygiene and mucosal inflammation, titanium was superior to reinforced composite resin in implant-supported fixed prostheses for edentulous subjects, and the short-term use of acrylic resin was superior to the use of reinforced composite resin.
© 2012 John Wiley & Sons A/S.

Entities:  

Keywords:  blood flow; full-arch implant-supported fixed prostheses; laser speckle imaging; mucosal surface; plaque area index

Mesh:

Substances:

Year:  2012        PMID: 22804816     DOI: 10.1111/j.1600-0501.2012.02523.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Evaluation of clinical performance and survival rate of Straumann dental implants in Saudi Population based on cross-sectional study.

Authors:  Reham Al Jasser; Mohammed AlSarhan; Dalal Alotaibi; Saleh Aloraini; Pradeep Koppolu; Sebastiano Andreana
Journal:  Sci Rep       Date:  2021-05-04       Impact factor: 4.379

2.  Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study.

Authors:  Giorgio Lombardo; Annarita Signoriello; Mauro Marincola; Pietro Liboni; Estevam A Bonfante; Pier F Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2021-11-18       Impact factor: 4.259

3.  Short and ultra-short (<6-mm) locking-taper implants supporting single crowns in posterior areas (part II): A 5-year retrospective study on periodontally healthy patients and patients with a history of periodontitis.

Authors:  Giorgio Lombardo; Annarita Signoriello; Alessia Pardo; Xiomara Zilena Serpa Romero; Luis Armando Vila Sierra; Luisa Arévalo Tovar; Mauro Marincola; Pier Francesco Nocini
Journal:  Clin Implant Dent Relat Res       Date:  2022-05-30       Impact factor: 4.259

4.  Microbiological and clinical evaluation of ultrasonic debridement with/without erythritol air polishing during supportive periodontal therapy in arches with full-arch fixed implant-supported prostheses: protocol for a randomised controlled trial.

Authors:  Jingwen Yang; Pingyi Jia; Qi Liu; Jianxia Hou; Zhaoguo Yue; Jianzhang Liu; Zhongning Liu; Lin Tang
Journal:  BMJ Open       Date:  2021-12-07       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.