| Literature DB >> 22801839 |
Martin S Spitzer1, Efdal Yoeruek, Martin A Leitritz, Peter Szurman, Karl U Bartz-Schmidt.
Abstract
We describe a new surgical technique for treating traumatic aniridia with aphakia and its results in a small consecutive case series. We attached a 3-piece acrylic intraocular lens through the haptics to a customized silicone iris prosthesis. The combined implant was inserted through a 5-mm incision and fixated with a transscleral suture in the ciliary sulcus using a knotless technique (Z suture). In all patients, the combined implant stayed firmly fixed within the sulcus and showed a stable and centered position without any tilt or torque during follow-up. Thus, managing posttraumatic aniridia with aphakia by means of haptic fixation of a foldable intraocular lens on a custom-tailored iris prosthesis is a promising approach for visual rehabilitation and cosmetic improvement.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22801839 DOI: 10.1001/archophthalmol.2011.1778
Source DB: PubMed Journal: Arch Ophthalmol ISSN: 0003-9950