Literature DB >> 22801521

Implantable ultra-low pulmonary pressure monitoring system for fetal surgery.

Mozziyar Etemadi, J Alex Heller, Samuel C Schecter, Eveline H Shue, Doug Miniati, Shuvo Roy.   

Abstract

Congenital pulmonary hypoplasia is a devastating condition affecting fetal and newborn pulmonary physiology, resulting in great morbidity and mortality. The fetal lung develops in a fluid-filled environment. In this work, we describe a novel, implantable pressure sensing and recording device which we use to study the pressures present in the fetal pulmonary tree throughout gestation. The system achieves 0.18 cm H2O resolution and can record for twenty one days continuously at 256 Hz. Sample tracings of in vivo fetal lamb recordings are shown.

Entities:  

Mesh:

Year:  2012        PMID: 22801521      PMCID: PMC4605429          DOI: 10.1109/TITB.2012.2207399

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  11 in total

1.  Lamb fetal pulmonary fluid. I. Validation and significance of method for determination of volume and volume change.

Authors:  E M Scarpelli; S Condorelli; E V Cosmi
Journal:  Pediatr Res       Date:  1975-04       Impact factor: 3.756

Review 2.  Fetal breathing and development of control of breathing.

Authors:  A H Jansen; V Chernick
Journal:  J Appl Physiol (1985)       Date:  1991-04

3.  Feasibility of in utero telemetric fetal ECG monitoring in a lamb model.

Authors:  Bart Hermans; Liesbeth Lewi; Jacques Jani; Frederik De Buck; Jan Deprest; Robert Puers
Journal:  Fetal Diagn Ther       Date:  2008-07-17       Impact factor: 2.587

4.  Implantable data logging system for heart rate and body temperature: its application to the estimation of field metabolic rates in Antarctic predators.

Authors:  A J Woakes; P J Butler; R M Bevan
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

Review 5.  The effects of mechanical forces on fetal lung growth.

Authors:  J A Kitterman
Journal:  Clin Perinatol       Date:  1996-12       Impact factor: 3.430

6.  Growth of the fetal lung.

Authors:  G C Liggins
Journal:  J Dev Physiol       Date:  1984-06

Review 7.  Implantable telemetry in biomedical research.

Authors:  J D Meindl; A J Ford
Journal:  IEEE Trans Biomed Eng       Date:  1984-12       Impact factor: 4.538

Review 8.  Regulation of lung expansion and lung growth before birth.

Authors:  R Harding; S B Hooper
Journal:  J Appl Physiol (1985)       Date:  1996-07

9.  Respiratory movements and rapid eye movement sleep in the foetal lamb.

Authors:  G S Dawes; H E Fox; B M Leduc; G C Liggins; R T Richards
Journal:  J Physiol       Date:  1972-01       Impact factor: 5.182

10.  The Responsivity of a Miniaturized Passive Implantable Wireless Pressure Sensor.

Authors:  Hao Jiang; Di Lan; Ken Goldman; Mozziyar Etemadi; Hamid Shahnasser; Shuvo Roy
Journal:  Proc IEEE Radio Wirel Symp       Date:  2011
View more
  2 in total

1.  A Wearable Patch to Enable Long-Term Monitoring of Environmental, Activity and Hemodynamics Variables.

Authors:  Mozziyar Etemadi; Omer T Inan; J Alex Heller; Sinan Hersek; Liviu Klein; Shuvo Roy
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2015-05-12       Impact factor: 3.833

Review 2.  Probing the Electrophysiology of the Developing Heart.

Authors:  Michiko Watanabe; Andrew M Rollins; Luis Polo-Parada; Pei Ma; Shi Gu; Michael W Jenkins
Journal:  J Cardiovasc Dev Dis       Date:  2016-03-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.