Literature DB >> 22800747

[Unilateral pedicle screw fixation through the pedicle of fractured vertebra in combination with the short segment of pedicle screw in the treatment of thoracolumbar fracture of mild to moderate instability].

Zhi-li Zeng1, Li-ming Cheng, Lie Qian, Yong-wei Jia, Yan Yu, Jian-jie Wang.   

Abstract

OBJECTIVE: To evaluate the efficacy of unilateral pedicle screw fixation through the pedicle of fractured vertebra in combination with the short segment of pedicle screw in the treatment of thoracolumbar fracture of mild to moderate instability.
METHODS: Twenty-six patients with single segment thoracolumbar fracture received unilateral pedicle screw fixation through the pedicle of fractured vertebra in combination with the short segment of pedicle screw from January 2008 to December 2009. There were 16 patients were male and 10 were female with an average age of 47.3 years (range from 39 to 60 years). Fracture severity score was constructed by using the load-sharing classification (4 points for 2 cases, 5 points for 14 cases, 6 points for 10 cases). By Frankel assessment system, 2 cases were in grade C, 3 in grade D, 21 in grade E. The assessment included anterior vertebral body height, the sagittal Cobb angle, the restoration of nervous function, visual analogue score (VAS) and Oswestry disability index (ODI).
RESULTS: The follow-up after the surgery was 13 - 26 months, with an average of 18.6 months. There were no fixation failure, defined as implant failure or ≥ 10° correction loss. The neurological status of 4 patients, who had an associated neurologic deficit preoperatively, was completely recovered. The Frankel grade of another case was re-rated D from the original C. The mean anterior vertebral body height increased from 57.0% ± 6.3% before the surgery to 93.1% ± 1.7% at the last follow-up(F = 455.276, P < 0.05). The sagittal Cobb angle decreased from 15.6° ± 4.7° before the surgery to 2.6° ± 5.2° at the last follow-up (F = 34.623, P < 0.05). VAS and ODI were 1.0 ± 0.7 and 17.0 ± 5.9 at the last follow-up.
CONCLUSION: Unilateral pedicle screw fixation through the pedicle of fractured vertebra combined with the short segment of pedicle screw is effective for thoracolumbar fracture with mild to moderate instability.

Entities:  

Mesh:

Year:  2012        PMID: 22800747

Source DB:  PubMed          Journal:  Zhonghua Wai Ke Za Zhi        ISSN: 0529-5815


  1 in total

1.  Minimally invasive pedicle screw fixation, including the fractured vertebra, combined with percutaneous vertebroplasty for treatment of acute thoracolumbar osteoporotic compression fracture in middle-age and elderly individuals: A prospective clinical study.

Authors:  Hong Liu; Jin-Wei Xu; Guan-Rong Sun; Wei-Feng Shi; Li-Ming Xiang; Shan Chen
Journal:  Medicine (Baltimore)       Date:  2022-03-11       Impact factor: 1.817