Literature DB >> 2279982

A parametric study of the factors affecting the fatigue strength of porous coated Ti-6A1-4V implant alloy.

D H Kohn1, P Ducheyne.   

Abstract

The high cycle fatigue strength of porous coated Ti-6A1-4V is approximately 75% less than the fatigue strength of uncoated Ti-6A1-4V. This study separates the effects of three parameters thought to be responsible for this reduction: interfacial geometry, microstructure, and surface alterations brought about by sintering. To achieve the goal of one parameter variations, hydrogen-alloying treatments, which refined the lamellar microstructure of beta-annealed and porous coated Ti-6A1-4V, were formulated. The fatigue strength of smooth-surfaced Ti-6A1-4V subjected to hydrogen-alloying treatments is 643-669 MPa, significantly greater than the fatigue strength of beta-annealed Ti-6A1-4V (497 MPa) and also greater than the fatigue strength of pre-annealed, equiaxed Ti-6A1-4V (590 MPa). The fatigue strength of porous coated Ti-6A1-4V, however, is independent of microstructure. This leads to the conclusion that the notch effect of the surface porosity does not allow the material to take advantage of the superior fatigue crack initiation resistance of a refined alpha-grain size. Thus, sinternecks acts as initiated microcracks and fatigue of porous coated Ti-6A1-4V is propagation controlled.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2279982     DOI: 10.1002/jbm.820241106

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Gradient surface porosity in titanium dental implants: relation between processing parameters and microstructure.

Authors:  M G Kutty; S Bhaduri; S B Bhaduri
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

2.  Porous tantalum structures for bone implants: fabrication, mechanical and in vitro biological properties.

Authors:  Vamsi Krishna Balla; Subhadip Bodhak; Susmita Bose; Amit Bandyopadhyay
Journal:  Acta Biomater       Date:  2010-02-02       Impact factor: 8.947

3.  Direct laser processing of a tantalum coating on titanium for bone replacement structures.

Authors:  Vamsi Krishna Balla; Shashwat Banerjee; Susmita Bose; Amit Bandyopadhyay
Journal:  Acta Biomater       Date:  2009-12-04       Impact factor: 8.947

Review 4.  Dental implant systems.

Authors:  Yoshiki Oshida; Elif B Tuna; Oya Aktören; Koray Gençay
Journal:  Int J Mol Sci       Date:  2010-04-12       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.