Literature DB >> 22795727

Mechanical torque measurement for in vivo quantification of bone strength in the proximal femur.

Marc Andreas Mueller1, Clemens Hengg, Michael Hirschmann, Denise Schmid, Christoph Sprecher, Laurent Audigé, Norbert Suhm.   

Abstract

INTRODUCTION: Bone strength determines fracture risk and fixation strength of osteosynthesis implants. In vivo, bone strength is currently measured indirectly by quantifying bone mineral density (BMD) which is however only one determinant of the bone's biomechanical competence besides the bone's macro- and micro-architecture and tissue related parameters. We have developed a measurement principle (DensiProbe™ Hip) for direct, mechanical quantification of bone strength within the proximal femur upon hip fracture fixation. Previous cadaver tests indicated a close correlation between DensiProbe™ Hip measurements, 3D micro-CT analysis and biomechanical indicators of bone strength. The goal of this study was to correlate DensiProbe™ Hip measurements with areal bone mineral density (BMD).
METHODS: Forty-three hip fracture patients were included in this study. Intraoperatively, DensiProbe™ Hip was inserted to the subsequent hip screw tip position within the femoral head. Peak torque to breakaway of local cancellous bone was registered. Thirty-seven patients underwent areal BMD measurements of the contralateral proximal femur. Failure of fixation was assessed radio graphically 6 and 12 weeks postoperatively.
RESULTS: Peak torque and femoral neck BMD showed significant correlations (R=0.60, P=0.0001). In regression analysis, areal BMD explained 46% of femoral neck BMD variance in a quadratic relationship. Throughout the 12-week follow-up period, no failure of fixation was observed.
CONCLUSIONS: DensiProbe™ Hip may capture variations of bone strength beyond areal BMD which are currently difficult to measure in vivo. A multicenter study will clarify if peak torque predicts fixation failure.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22795727     DOI: 10.1016/j.injury.2012.06.014

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  3 in total

1.  Bone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements.

Authors:  Matthias C M Klotz; Nicholas A Beckmann; Rudi G Bitsch; Elisabeth Seebach; Tobias Reiner; Sebastian Jäger
Journal:  J Orthop Surg Res       Date:  2014-11-13       Impact factor: 2.359

2.  Regional apparent density correlations within the proximal humerus.

Authors:  Jacob M Reeves; Tom Vanasse; Chris Roche; George S Athwal; James A Johnson; Kenneth J Faber; G Daniel G Langohr
Journal:  JSES Int       Date:  2021-02-09

3.  Are radiographic indices reliable indicators for quantitative bone mineral density and vitamin D status after femoral neck fractures? A retrospective study in 112 elderly patients.

Authors:  Andy K S Yeo; Annette B Ahrberg; Jan D Theopold; Sebastian Ewens; Gudrun Borte; Christoph Josten; Johannes K M Fakler
Journal:  Patient Saf Surg       Date:  2015-11-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.