Literature DB >> 22794209

Assessment of the separation incidence of mtwo files used with preflaring: prospective clinical study.

Iracema C Ehrhardt1, Mário L Zuolo, Rodrigo S Cunha, Alexandre S De Martin, Daniel Kherlakian, Maria Cristina C de Carvalho, Carlos Eduardo da S Bueno.   

Abstract

INTRODUCTION: The Mtwo rotary system was designed to be used at full length without performing previous cervical enlargement or creating a manual glide path. However, to our knowledge, no study has investigated whether preflaring influences instrument fatigue. The purpose of this clinical study was thus to evaluate the incidence of separation of Mtwo instruments during the preparation of mandibular and maxillary molars and bicuspids that was preceded by cervical preflaring.
METHODS: A total of 556 treatments were performed by 6 endodontists after calibration. Cervical enlargement and exploration with hand files were undertaken before using the rotary files. The canals were negotiated with small K-type hand files. Cervical and middle thirds were prepared with hand files and Gates-Glidden burs. Irrigation was performed with 2 mL of 2.5% NaOCl after each instrument. The working length was established, and the apical third was prepared with Flexofiles until a #15 file could reach the working length, establishing a glide path. The Mtwo instruments were used following manufacturer's recommendations and disposed of after being used in 5 teeth. Each file was examined under ×8 magnification after use. In cases of file deformation or separation, the entire file kit was no longer used, except when using the 10.04 file. Because of its high failure rate, which is well-established in the related literature, this instrument could be replaced at any time.
RESULTS: Separation and deformation rates were 1.98% and 28.78%, respectively. Ten of the total separations observed occurred with the 10.04 file (90.01%) and one with the 15.05 file (9.09%).
CONCLUSIONS: The use of Mtwo rotary instruments preceded by cervical preflaring with manual files and Gates-Glidden burs provides a low separation incidence.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22794209     DOI: 10.1016/j.joen.2012.05.001

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Quantitative evaluation of apical extrusion of intracanal bacteria using K3, Mtwo, RaCe and protaper rotary systems: An in vitro study.

Authors:  Roopadevi Garlapati; Bhuvan Shome Venigalla; Jayaprakash D Patil; Rvsc Raju; Chintamani Rammohan
Journal:  J Conserv Dent       Date:  2013-07

2.  Efficacy of LA Axxess burs, Gates Glidden drills and Protaper Sx in obtaining straight line access in mesiobuccal roots of mandibular first molars: A cone-beam computed tomography assessment.

Authors:  Promila Verma; Rhythm Bains; A P Tikku; Anil Chandra; Shibha Mehta
Journal:  Eur J Dent       Date:  2016 Oct-Dec

3.  Cyclic Fatigue Resistance of WaveOne Gold, ProDesign R and ProDesign Logic Files in Curved Canals In Vitro.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Juliana Ouro Preto Lira; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2017

4.  Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study.

Authors:  Liliana Machado Ruivo; Marcos de Azevedo Rios; Alexandre Mascarenhas Villela; Alexandre Sigrist de Martin; Augusto Shoji Kato; Rina Andrea Pelegrine; Ana Flávia Almeida Barbosa; Emmanuel João Nogueira Leal Silva; Carlos Eduardo da Silveira Bueno
Journal:  Restor Dent Endod       Date:  2021-09-09

5.  Effects of Glide Path on the Centering Ability and Preparation Time of Two Reciprocating Instruments.

Authors:  Marcelo Santos Coelho; Carlos Eduardo Fontana; Augusto Shoji Kato; Alexandre Sigrist de Martin; Carlos Eduardo da Silveira Bueno
Journal:  Iran Endod J       Date:  2015-12-24

6.  Influence of a glide path on the dentinal crack formation of ProTaper Next system.

Authors:  Sevinç Aktemur Türker; Emel Uzunoğlu
Journal:  Restor Dent Endod       Date:  2015-09-02

7.  Cyclic Fatigue Resistance of Mtwo Rotary Instruments with two Different Instrumentation Techniques.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Diego Felipe Brandão de Magalhães; de Albuquerque Diana Santana; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2018

8.  Influence of reuse and cervical preflaring on the fracture strength of reciprocating instruments.

Authors:  Claudio Maniglia-Ferreira; Fabio de Almeida Gomes; Tatyana Ximenes; Murilo Alves Teixeira Neto; Thiane Elys Arruda; Giovani Gonçalves Ribamar; Luis Flávio Gaspar Herculano
Journal:  Eur J Dent       Date:  2017 Jan-Mar

Review 9.  Separation of Nickel-Titanium Rotary and Reciprocating Instruments: A Mini-Review of Clinical Studies.

Authors:  Marcelo Santos Coelho; Marcos de Azevêdo Rios; Carlos Eduardo da Silveira Bueno
Journal:  Open Dent J       Date:  2018-10-25

10.  Influence of cervical preflaring and root canal preparation on the fracture resistance of endodontically treated teeth.

Authors:  Paula Barcellos da Silva; Simone Ferreti Duarte; Murilo Priori Alcalde; Marco Antonio Húngaro Duarte; Rodrigo Ricci Vivan; Ricardo Abreu da Rosa; Marcus Vinícius Reis Só; Angela Longo do Nascimento
Journal:  BMC Oral Health       Date:  2020-04-16       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.