Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN™ prosthesis.

Arnaud Van Linden1, Jörg Kempfert, Johannes Blumenstein, Ardawan Rastan, David Holzhey, Sven Lehmann, Friedrich W Mohr, Thomas Walther.   

Abstract

OBJECTIVES: Prosthesis-patient mismatch (PPM) is defined as a too small effective orifice area (EOA) of the prosthetic valve in relation to the patient's body size and has been documented to be related to adverse outcomes after conventional aortic valve replacement (AVR). Aim of this study was to analyze the incidence of PPM after transcatheter aortic valve implantation (T-AVI) using the Edwards SAPIEN prosthesis and its relation to postoperative outcome.
METHODS: 200 consecutive high-risk patients underwent transapical aortic valve implantation (TA-AVI) between February 2006 and January 2009 and fulfilled 1 year follow-up were included. Severe PPM was defined as indexed EOA (EOAi) <0.65 cm2/m2 and moderate PPM as EOAi = 0.65-0.85 cm2/m2, EOA was calculated from transthoracic echocardiographic (TTE) measurements using the continuity equation. Total 112 patients with sufficient postoperative TTE image quality formed the study group.
RESULTS: EOAi increased from 0.3 ± 0.1 cm2/m2 (preoperatively) to 1.1 ± 0.4 cm2/m2 after TA-AVI (p < 0.001). According to the standard definitions, PPM was seen in 38.4% of the patients and 9.8% presented with severe PPM. The occurrence of PPM had neither an effect on clinical outcome in terms of NYHA class nor on survival. Patients with PPM had significantly higher postoperative transprosthetic gradients (mean gradient 10.4 ± 4.1 versus 7.1 ± 3.0 mm Hg, p < 0.001). Based on the in vitro EOA data obtained from pulse duplicator measurements, however, none of the patients was judged to have PPM.
CONCLUSION: Transcatheter AVI provides good antegrade hemodynamic function and EOAi improves significantly. According to standardized evaluations PPM occurs after TA-AVI, but it is not associated with adverse outcomes. Thus use of the continuity equation may not adequately reflect the situation after T-AVI or the current definition of PPM is not suitable for T-AVI prostheses. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2012        PMID: 22791205     DOI: 10.1055/s-0032-1311534

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  8 in total

1.  Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing.

Authors:  Won-Keun Kim; Alexander Meyer; Helge Möllmann; Andreas Rolf; Susanne Möllmann; Johannes Blumenstein; Arnaud Van Linden; Christian W Hamm; Thomas Walther; Jörg Kempfert
Journal:  Clin Res Cardiol       Date:  2016-02-18       Impact factor: 5.460

2.  Transapical transcatheter aortic valve implantation: the front door approach captures the world.

Authors:  Barbara E Stähli; Lukas Altwegg
Journal:  Cardiovasc Diagn Ther       Date:  2012-12

3.  Incidence and sequelae of prosthesis-patient mismatch in transcatheter versus surgical valve replacement in high-risk patients with severe aortic stenosis: a PARTNER trial cohort--a analysis.

Authors:  Philippe Pibarot; Neil J Weissman; William J Stewart; Rebecca T Hahn; Brian R Lindman; Thomas McAndrew; Susheel K Kodali; Michael J Mack; Vinod H Thourani; D Craig Miller; Lars G Svensson; Howard C Herrmann; Craig R Smith; Josep Rodés-Cabau; John Webb; Scott Lim; Ke Xu; Irene Hueter; Pamela S Douglas; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2014-09-30       Impact factor: 24.094

4.  Impact of Prosthesis-Patient Mismatch on Left Ventricular Myocardial Mechanics After Transcatheter Aortic Valve Replacement.

Authors:  Frédéric Poulin; Teerapat Yingchoncharoen; William M Wilson; Eric M Horlick; Philippe Généreux; E Murat Tuzcu; William Stewart; Mark D Osten; Anna Woo; Paaladinesh Thavendiranathan
Journal:  J Am Heart Assoc       Date:  2016-02-08       Impact factor: 5.501

5.  Impact of Prosthesis-Patient Mismatch on 1-Year Outcomes after Transcatheter Aortic Valve Implantation: Meta-analysis of 71,106 Patients.

Authors:  Michel Pompeu Barros Oliveira Sá; Luiz Rafael Pereira Cavalcanti; Felipe Augusto Santos Sarargiotto; Álvaro Monteiro Perazzo; Sérgio da Costa Rayol; Roberto Gouveia Silva Diniz; Frederico Browne Correia Araújo Sá; Alexandre Motta Menezes; Ricardo Carvalho Lima
Journal:  Braz J Cardiovasc Surg       Date:  2019-06-01

6.  Hemodynamic Performance of Two Current-Generation Transcatheter Heart Valve Prostheses in Severely Calcified Aortic Valve Stenosis.

Authors:  Max Potratz; Kawa Mohemed; Hazem Omran; Lasha Gortamashvili; Kai Peter Friedrichs; Werner Scholtz; Smita Scholtz; Volker Rudolph; Cornelia Piper; Tomasz Gilis-Januszewski; René Schramm; Nobuyuki Furukawa; Jan Gummert; Sabine Bleiziffer; Tanja Katharina Rudolph
Journal:  J Clin Med       Date:  2022-08-05       Impact factor: 4.964

7.  Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Authors:  Yan-Biao Liao; Yi-Jian Li; Li Jun-Li; Zhen-Gang Zhao; Xin Wei; Jiay-Yu Tsauo; Tian-Yuan Xiong; Yuan-Ning Xu; Yuan Feng; Mao Chen
Journal:  Sci Rep       Date:  2017-11-08       Impact factor: 4.379

8.  Incidence, predictors, and outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement: A meta-analysis.

Authors:  Shixin He; Zhenfei Fang
Journal:  Medicine (Baltimore)       Date:  2020-06-12       Impact factor: 1.817

  8 in total