Literature DB >> 22789392

Alveolar osteotomy associated with resorbable non-ceramic hydroxylapatite or intra-oral autogenous bone for height augmentation in posterior mandibular sites: a split-mouth prospective study.

Paulo Y Kawakami1, Alexandre M Dottore, Karen Bechara, Magda Feres, Jamil A Shibli.   

Abstract

BACKGROUND: The presence of the inferior alveolar nerve within the body of the mandible could jeopardize the placement of dental implants. Previous studies have shown that the interpositional osteotomy for posterior mandible ridge augmentation could be a predictable procedure. Nevertheless, there are few prospective, controlled, and randomized studies that evaluated this technique using different bone graft materials.
PURPOSE: This prospective, controlled split-mouth study evaluated, using tomographic and Resonance Frequency Analyses (RFA), implants placed in the augmented mandibular area.
MATERIAL AND METHODS: Alveolar augmentation osteotomies were performed bilaterally in 12 partially edentulous mandibular patients in a split-mouth design. The alveolar segmental osteotomies were assigned in two groups: test group, interpositional non-ceramic hydroxylapatite bone graft, and control group, interpositional intra-oral autogenous bone graft. After 6 months healing, implants were placed. The tomographic measurements of bone gain were recorded at baseline and 6 months after surgery, when the implants were placed. At 12 months after osteotomy, RFA were performed for each implant.
RESULTS: The mean of bone gain 6.5 ± 2.4 mm and 7.0 ± 1.76 mm to control and test group, respectively (P > 0.05). RFA values between groups were similar at baseline and 12 months follow-up (P > 0.05).
CONCLUSION: Alveolar osteotomies associated with sandwich interpositional bone graft, independently of bone graft, resulted in bone formation over a period of 12 months.
© 2012 John Wiley & Sons A/S.

Entities:  

Keywords:  autogenous bone graft; dental implants; inlay bone grafts; non-ceramic hydroxylapatite; posterior mandible; segmented osteotomy

Mesh:

Substances:

Year:  2012        PMID: 22789392     DOI: 10.1111/j.1600-0501.2012.02530.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

Review 2.  Types of devices used in ridge split procedure for alveolar bone expansion: A systematic review.

Authors:  Nayansi Jha; Eun Ha Choi; Nagendra Kumar Kaushik; Jae Jun Ryu
Journal:  PLoS One       Date:  2017-07-21       Impact factor: 3.240

Review 3.  Long-term effects of vertical bone augmentation: a systematic review.

Authors:  Johan Anton Jochum Keestra; Obada Barry; Lianne de Jong; Gerhard Wahl
Journal:  J Appl Oral Sci       Date:  2016 Jan-Feb       Impact factor: 2.698

Review 4.  Survival Rates of Dental Implants in Autogenous and Allogeneic Bone Blocks: A Systematic Review.

Authors:  Phil Donkiewicz; Korbinian Benz; Anita Kloss-Brandstätter; Jochen Jackowski
Journal:  Medicina (Kaunas)       Date:  2021-12-20       Impact factor: 2.430

  4 in total