SUMMARY The following parameters were varied: 1) irradiation technique: top and bottom polymerization according to the ISO standard, and polymerization from only the top, simulating clinical situations; 2) polymerization time: 5, 10, 20, and 40 seconds; 3) storage conditions: 24 hours in distilled water, thermocycling followed by storage for four weeks in artificial saliva or alcohol. Flexural strength (FS), flexural modulus (Eflexural), indentation modulus (E), Vickers hardness (HV), and degree of conversion (DC) were measured. The laboratory results were similar to those measured by mimicking clinical conditions only at high polymerization times and mild storage conditions (20 seconds and 40 seconds and storage for 24 hours in water, and 40 seconds with aging and storing in saliva). Significantly higher DC values were measured on the top than on the bottom of a 2-mm layer for all polymerization times. Overall, 5-second and 10-second irradiation times induced significantly lower DC values compared to the currently recommended polymerization times of 20 and 40 seconds at both the top and bottom of the samples. The initial DC differences as a function of irradiation time are leveled at 24 hours of storage but seem to do well in predicting long-term material behavior. A minimum irradiation time of 20 seconds is necessary clinically to achieve the best mechanical properties with modern high-intensity light emitting diode (LED) units.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22788727     DOI: 10.2341/12-084-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Effect of different curing protocols on the mechanical properties of low-viscosity bulk-fill composites.

Authors:  Nicoleta Ilie; Katharina Stark
Journal:  Clin Oral Investig       Date:  2014-05-25       Impact factor: 3.573

Review 2.  The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review.

Authors:  Christie M Tafur-Zelada; Oscar Carvalho; Filipe S Silva; Bruno Henriques; Mutlu Özcan; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-03-30       Impact factor: 3.573

3.  The Effect of Shade and Thickness on the Depth of Cure of Bulk-Fill Composites with Different Viscosities.

Authors:  Maryam Novin Rooz; Atefeh Yousefi Jordehi
Journal:  J Dent (Shiraz)       Date:  2020-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.