Literature DB >> 22783048

Carbon dioxide insufflation during colonoscopy in deeply sedated patients.

Rajvinder Singh1, Eu Nice Neo, Nazree Nordeen, Ganesananthan Shanmuganathan, Angelie Ashby, Sharon Drummond, Garry Nind, Elizabeth Murphy, Andrew Luck, Graeme Tucker, William Tam.   

Abstract

AIM: To compare the impact of carbon dioxide (CO₂) and air insufflation on patient tolerance/safety in deeply sedated patients undergoing colonoscopy.
METHODS: Patients referred for colonoscopy were randomized to receive either CO₂ or air insufflation during the procedure. Both the colonoscopist and patient were blinded to the type of gas used. During the procedure, insertion and withdrawal times, caecal intubation rates, total sedation given and capnography readings were recorded. The level of sedation and magnitude of patient discomfort during the procedure was assessed by a nurse using a visual analogue scale (VAS) (0-3). Patients then graded their level of discomfort and abdominal bloating using a similar VAS. Complications during and after the procedure were recorded.
RESULTS: A total of 142 patients were randomized with 72 in the air arm and 70 in the CO₂ arm. Mean age between the two study groups were similar. Insertion time to the caecum was quicker in the CO₂ group at 7.3 min vs 9.9 min with air (P = 0.0083). The average withdrawal times were not significantly different between the two groups. Caecal intubation rates were 94.4% and 100% in the air and CO₂ groups respectively (P = 0.012). The level of discomfort assessed by the nurse was 0.69 (air) and 0.39 (CO₂) (P = 0.0155) and by the patient 0.82 (air) and 0.46 (CO₂) (P = 0.0228). The level of abdominal bloating was 0.97 (air) and 0.36 (CO₂) (P = 0.001). Capnography readings trended to be higher in the CO₂ group at the commencement, caecal intubation, and conclusion of the procedure, even though this was not significantly different when compared to readings obtained during air insufflation. There were no complications in both arms.
CONCLUSION: CO₂ insufflation during colonoscopy is more efficacious than air, allowing quicker and better cecal intubation rates. Abdominal discomfort and bloating were significantly less with CO₂ insufflation.

Entities:  

Keywords:  Air; Carbon dioxide; Colonoscopy; Efficacy; Insufflations; Patient tolerance; Safety

Mesh:

Substances:

Year:  2012        PMID: 22783048      PMCID: PMC3391761          DOI: 10.3748/wjg.v18.i25.3250

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  9 in total

1.  Randomized, controlled trial of carbon dioxide insufflation during colonoscopy.

Authors:  J Church; C Delaney
Journal:  Dis Colon Rectum       Date:  2003-03       Impact factor: 4.585

2.  NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.

Authors:  M Bretthauer; E Thiis-Evensen; G Huppertz-Hauss; L Gisselsson; T Grotmol; E Skovlund; G Hoff
Journal:  Gut       Date:  2002-05       Impact factor: 23.059

3.  A pilot study to assess the safety and efficacy of carbon dioxide insufflation during colorectal endoscopic submucosal dissection with the patient under conscious sedation.

Authors:  Yutaka Saito; Toshio Uraoka; Takahisa Matsuda; Fabian Emura; Hisatomo Ikehara; Yumi Mashimo; Tsuyoshi Kikuchi; Takahiro Kozu; Daizo Saito
Journal:  Gastrointest Endosc       Date:  2007-03       Impact factor: 9.427

4.  Propofol versus midazolam/meperidine for outpatient colonoscopy: administration by nurses supervised by endoscopists.

Authors:  Brian W Sipe; Douglas K Rex; Danielle Latinovich; Chris Overley; Karen Kinser; Lisa Bratcher; David Kareken
Journal:  Gastrointest Endosc       Date:  2002-06       Impact factor: 9.427

5.  Carbon dioxide insufflation for more comfortable colonoscopy.

Authors:  A M Hussein; C I Bartram; C B Williams
Journal:  Gastrointest Endosc       Date:  1984-04       Impact factor: 9.427

6.  Towards painless colonoscopy: a randomized controlled trial on carbon dioxide-insufflating colonoscopy.

Authors:  James C H Wong; Kevin K Yau; Hester Y S Cheung; Denis C T Wong; Cliff C Chung; Michael K W Li
Journal:  ANZ J Surg       Date:  2008-10       Impact factor: 1.872

7.  Minimizing postcolonoscopy abdominal pain by using CO(2) insufflation: a prospective, randomized, double blind, controlled trial evaluating a new commercially available CO(2) delivery system.

Authors:  Katica Sumanac; Ian Zealley; Bruce M Fox; John Rawlinson; Bruno Salena; John K Marshall; Giles W Stevenson; Richard H Hunt
Journal:  Gastrointest Endosc       Date:  2002-08       Impact factor: 9.427

8.  Pain following colonoscopy: elimination with carbon dioxide.

Authors:  G W Stevenson; J A Wilson; J Wilkinson; G Norman; R L Goodacre
Journal:  Gastrointest Endosc       Date:  1992 Sep-Oct       Impact factor: 9.427

Review 9.  The use of carbon dioxide for insufflation during GI endoscopy: a systematic review.

Authors:  Evan S Dellon; James S Hawk; Ian S Grimm; Nicholas J Shaheen
Journal:  Gastrointest Endosc       Date:  2009-01-18       Impact factor: 9.427

  9 in total
  3 in total

Review 1.  Endoscopy and polyps-diagnostic and therapeutic advances in management.

Authors:  Scott R Steele; Eric K Johnson; Bradley Champagne; Brad Davis; Sang Lee; David Rivadeneira; Howard Ross; Dana A Hayden; Justin A Maykel
Journal:  World J Gastroenterol       Date:  2013-07-21       Impact factor: 5.742

Review 2.  Is the type of insufflation a key issue in gastro-intestinal endoscopy?

Authors:  Amy C Lord; Stefan Riss
Journal:  World J Gastroenterol       Date:  2014-03-07       Impact factor: 5.742

3.  A meta-analysis of carbon dioxide versus room air insufflation on patient comfort and key performance indicators at colonoscopy.

Authors:  Ailín C Rogers; Dayna Van De Hoef; Shaheel M Sahebally; Des C Winter
Journal:  Int J Colorectal Dis       Date:  2020-01-03       Impact factor: 2.571

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.