Evaluation of blood collection filter papers for HIV-1 DNA PCR.

Silvina Masciotra1, Samoel Khamadi, Ebi Bilé, Adrian Puren, Peter Fonjungo, Shon Nguyen, Mulu Girma, Robert Downing, Artur Ramos, Shambavi Subbarao, Dennis Ellenberger.   

Abstract

BACKGROUND: The collection of dried blood spots (DBS) on Whatman 903 cards has facilitated for years the detection of HIV-1 in infants by DNA PCR as early as 4-6 weeks after birth in resource-limited settings (RLS), but alternate blood collection devices are proving to be necessary.
OBJECTIVES: The qualitative detection of HIV-1 DNA by PCR from DBS prepared on three commercially available blood collection cards was evaluated at the Centers for Disease Control and Prevention (CDC) and in four laboratories in Africa. STUDY
DESIGN: DBS were prepared on Ahlstrom grade 226, Munktell TFN and Whatman 903, and stored under a variety of conditions. DBS were stored at ambient temperature (RT), 37°C with high humidity, and -20°C for varying lengths of time. The presence of HIV-1 DNA was tested using Roche Amplicor HIV-1 DNA (v 1.5) weekly for 4 weeks and at weeks 8 and 12 (RT and 37°C), at weeks 4, 8, and 18 (-20°C) of storage. DBS specimens were also tested after international shipment at RT. In addition, after nearly 3 years storage at -20°C, DBS were also evaluated independently using the COBAS Ampliprep/TaqMan HIV-1 Qual and Abbott RealTime HIV-1 Qualitative tests.
RESULTS: HIV-1 DNA was detected equally well on the three blood collection cards regardless of storage conditions and PCR assay.
CONCLUSIONS: Ahlstrom 226 and Munktell TFN papers were comparable to Whatman 903 for HIV-1 DNA detection and may be considered as optional blood collection devices in resource-limited countries. Published by Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22776163     DOI: 10.1016/j.jcv.2012.06.010

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  5 in total

1.  Correlation of serum and dried blood spot results for quantitation of Schistosoma circulating anodic antigen: a proof of principle.

Authors:  Jennifer A Downs; Paul L A M Corstjens; Julius Mngara; Peter Lutonja; Raphael Isingo; Mark Urassa; Dieuwke Kornelis; Govert J van Dam
Journal:  Acta Trop       Date:  2015-07-03       Impact factor: 3.112

Review 2.  Diagnosis of Human Immunodeficiency Virus Infection.

Authors:  Bharat S Parekh; Chin-Yih Ou; Peter N Fonjungo; Mireille B Kalou; Erin Rottinghaus; Adrian Puren; Heather Alexander; Mackenzie Hurlston Cox; John N Nkengasong
Journal:  Clin Microbiol Rev       Date:  2018-11-28       Impact factor: 26.132

3.  Field evaluation of Abbott Real Time HIV-1 Qualitative test for early infant diagnosis using dried blood spots samples in comparison to Roche COBAS Ampliprep/COBAS TaqMan HIV-1 Qual test in Kenya.

Authors:  Joy Chang; Kenneth Omuomo; Emily Anyango; Leonard Kingwara; Frank Basiye; Alex Morwabe; Vedapuri Shanmugam; Shon Nguyen; Jennifer Sabatier; Clement Zeh; Dennis Ellenberger
Journal:  J Virol Methods       Date:  2014-04-13       Impact factor: 2.014

4.  Dried blood spots--preparing and processing for use in immunoassays and in molecular techniques.

Authors:  Nico Grüner; Oumaima Stambouli; R Stefan Ross
Journal:  J Vis Exp       Date:  2015-03-13       Impact factor: 1.355

5.  Dried Saliva Spots: A Robust Method for Detecting Streptococcus pneumoniae Carriage by PCR.

Authors:  Cassandra L Krone; Anna E Oja; Kirsten van de Groep; Elisabeth A M Sanders; Debby Bogaert; Krzysztof Trzciński
Journal:  Int J Mol Sci       Date:  2016-03-05       Impact factor: 5.923