Literature DB >> 22767302

Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study.

Giovanna Ferraioli1, Carmine Tinelli, Barbara Dal Bello, Mabel Zicchetti, Gaetano Filice, Carlo Filice.   

Abstract

UNLABELLED: Real-time shear wave elastography (SWE) is a novel, noninvasive method to assess liver fibrosis by measuring liver stiffness. This single-center study was conducted to assess the accuracy of SWE in patients with chronic hepatitis C (CHC), in comparison with transient elastography (TE), by using liver biopsy (LB) as the reference standard. Consecutive patients with CHC scheduled for LB by referring physicians were studied. One hundred and twenty-one patients met inclusion criteria. On the same day, real-time SWE using the ultrasound (US) system, Aixplorer (SuperSonic Imagine S.A., Aix-en-Provence, France), TE using FibroScan (Echosens, Paris, France), and US-assisted LB were consecutively performed. Fibrosis was staged according to the METAVIR scoring system. Analyses of receiver operating characteristic (ROC) curve were performed to calculate optimal area under the ROC curve (AUROC) for F0-F1 versus F2-F4, F0- F2 versus F3-F4, and F0-F3 versus F4 for both real-time SWE and TE. Liver stiffness values increased in parallel with degree of liver fibrosis, both with SWE and TE. AUROCs were 0.92 (95% confidence interval [CI]: 0.85-0.96) for SWE and 0.84 (95% CI: 0.76-0.90) for TE (P = 0.002), 0.98 (95% CI: 0.94-1.00) for SWE and 0.96 (95% CI: 0.90-0.99) for TE (P = 0.14), and 0.98 (95% CI: 0.93-1.00) for SWE and 0.96 (95% CI: 0.91-0.99) for TE (P = 0.48), when comparing F0-F1 versus F2- F4, F0- F2 versus F3-F4, and F0 -F3 versus F4, respectively.
CONCLUSION: The results of this study show that real-time SWE is more accurate than TE in assessing significant fibrosis (≥ F2). With respect to TE, SWE has the advantage of imaging liver stiffness in real time while guided by a B-mode image. Thus, the region of measurement can be guided with both anatomical and tissue stiffness information.
Copyright © 2012 American Association for the Study of Liver Diseases.

Entities:  

Mesh:

Year:  2012        PMID: 22767302     DOI: 10.1002/hep.25936

Source DB:  PubMed          Journal:  Hepatology        ISSN: 0270-9139            Impact factor:   17.425


  160 in total

1.  Shear-wave elastography for the estimation of liver fibrosis in chronic liver disease: determining accuracy and ideal site for measurement.

Authors:  Anthony E Samir; Manish Dhyani; Abhinav Vij; Atul K Bhan; Elkan F Halpern; Jorge Méndez-Navarro; Kathleen E Corey; Raymond T Chung
Journal:  Radiology       Date:  2014-11-13       Impact factor: 11.105

2.  The close linkage between the elasticity modulus measured by real-time mapping shear wave elastography and the presence of hepatocellular carcinoma in patients with a sustained virological response to interferon for chronic hepatitis C.

Authors:  Yasuharu Imai; Jun-Ichi Taira; Mayumi Okada; Mayumi Ando; Takatomo Sano; Yuhki Miyata; Katsutoshi Sugimoto; Ikuo Nakamura; Fuminori Moriyasu
Journal:  J Med Ultrason (2001)       Date:  2014-12-28       Impact factor: 1.314

Review 3.  Non-invasive diagnosis of liver fibrosis and cirrhosis.

Authors:  Yoav Lurie; Muriel Webb; Ruth Cytter-Kuint; Shimon Shteingart; Gerardo Z Lederkremer
Journal:  World J Gastroenterol       Date:  2015-11-07       Impact factor: 5.742

4.  Physiological ranges of matrix rigidity modulate primary mouse hepatocyte function in part through hepatocyte nuclear factor 4 alpha.

Authors:  Seema S Desai; Jason C Tung; Vivian X Zhou; James P Grenert; Yann Malato; Milad Rezvani; Regina Español-Suñer; Holger Willenbring; Valerie M Weaver; Tammy T Chang
Journal:  Hepatology       Date:  2016-03-09       Impact factor: 17.425

5.  Liver stiffness measurements with supersonic shear wave elastography in the diagnosis of biliary atresia: a comparative study with grey-scale US.

Authors:  Lu-Yao Zhou; Hong Jiang; Quan-Yuan Shan; Dong Chen; Xiao-Na Lin; Bao-Xian Liu; Xiao-Yan Xie
Journal:  Eur Radiol       Date:  2017-01-12       Impact factor: 5.315

6.  Shear wave elastography for liver fibrosis in chronic hepatitis B: Adapting the cut-offs to alanine aminotransferase levels improves accuracy.

Authors:  Jie Zeng; Jian Zheng; Jie-Yang Jin; Yong-Jiang Mao; Huan-Yi Guo; Ming-De Lu; Hai-Rong Zheng; Rong-Qin Zheng
Journal:  Eur Radiol       Date:  2018-07-23       Impact factor: 5.315

Review 7.  Non-invasive diagnosis of advanced fibrosis and cirrhosis.

Authors:  Suraj Sharma; Korosh Khalili; Geoffrey Christopher Nguyen
Journal:  World J Gastroenterol       Date:  2014-12-07       Impact factor: 5.742

8.  Assessment of fibrosis during the development of fatty liver in rabbits using real-time shear-wave elastography.

Authors:  Yong-Ping Lu; Jia Wei; Li-Rong Xu; Yue-Yue Tang; Yuan Yuan; Yong Zhang; Yun-Yan Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2014-12-06

9.  Shear wave elastography (SWE) of the spleen in patients with hepatitis B and C but without significant liver fibrosis.

Authors:  Aleksander Pawluś; Marcin Inglot; Mariusz Chabowski; Kinga Szymańska; Małgorzata Inglot; Mateusz Patyk; Joanna Słonina; Filipe Caseiro-Alves; Dariusz Janczak; Urszula Zaleska-Dorobisz
Journal:  Br J Radiol       Date:  2016-08-16       Impact factor: 3.039

10.  Effect of Fontan operation on liver stiffness in children with single ventricle physiology.

Authors:  Frank W DiPaola; Kurt R Schumacher; Caren S Goldberg; Joshua Friedland-Little; Aishwarya Parameswaran; Jonathan R Dillman
Journal:  Eur Radiol       Date:  2016-10-17       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.